Symptom
Possible Causes/Solutions
Does not rotate
Blown fuse
Test for 24V at plugs on directional valve while depressing foot switch
Incorrect pressure settings; reset
Does not rotate in one
direction
No electrical power to one side; test for 24V at plugs on directional valve while depressing
foot switch
Check if directional control valve shifts both ways while actuating foot switch in both
directions
Rotator chatters
Electrical short; back out flow controls
Pressure settings too high; reset
Power to both rotation solenoids at the same time; test for 24V at plugs on directional valve
while depressing foot switch
Rotates faster in one
direction
One flow control cartridge is set higher than the other; reset
Rotates too fast or too
slow
Flow control out of adjustment; reset
Rotation speed changed
from original setting
Jam nut loosened on rotation valve
Faulty cartridge (contamination)
Faulty directional control valve
Pressure set too low; reset
TROUBLE-SHOOTING GUIDE