© 2022 Genesis Attachments, LLC
Genesis GXT Mobile Shear 65
Follow steps 1 - 7 on the previous page to set the crossover reliefs.
If you cannot reach the pressure specified in the rotation valve setting table, adjust the
counterbalance valves using the following procedure:
Turn the crossover relief valve adjustment screws clockwise to their maximum setting, recording
the number of turns so they can later be returned to their original setting.
Adjust the counterbalance valves by turning the adjustment screws counter-clockwise until the
correct setting of 2500 PSI is reached.
Repeat steps 6 and 7 for setting the crossover reliefs.
For GXT 2055 and GXT 2555 with twin rotation motors, you must isolate one motor at a time to
check and adjust the valve settings. Follow the procedure for single motor set-up.
ROTATION WITH MOTION CONTROL VALVE
Flow Control
Valve
Relief Valve
1 turn = 400 PSI
Counterbalance
Valve
Relief Valve
1 turn = 400 PSI
Counterbalance
Valve