ROTATION WITH CROSSOVER RELIEF VALVE
Relief Valve
1 turn = 400 PSI
Relief Valve
1 turn = 400 PSI
Setting the Crossover Reliefs
1. Increase supply pressure to the rotation valve to 2500 PSI.
2. Install pressure gauges on relief test ports.
3. Plug hoses at motor or secure the shear from rotating.
4. Pressurize the valve to rotate.
5. Adjust the corresponding relief valve to 2200 psi.
6. Repeat for the other direction.
7. Reduce supply pressure to the pressure-reducer valve to 2000 psi.