Signal Output Circuit
LMD CANopen
Refer to the LMD MCode manual or the appropriate fieldbus manual for full setup and
configuration details for the inputs.
Input #
Function
Switch state
MCode setup string
(Is=[in #],[func],[active])
Notes
2
GP
normally open
IS=2, 0, 1
Set IN 2 as general purpose, active when high (switch closed)
3
GP
normally open
IS=3, 0, 1
Set IN 3 as general purpose, active when high (switch closed)
4
GP
normally open
IS=4, 0, 1
Set IN 4 as general purpose, active when high (switch closed)
Signal Output Circuit
The signal output provides indication of trip condition(s). The condition(s) which will trigger this
output are programmable.
The output is galvanically isolated by means of an optic isolation.
Signal output:
COLLECTOR
EMITTER
PLC input or
high speed latch
device
Analog Input
The
ANALOG _ IN
may be configured to detect one of three input types:
• 0 - 5V
• 0 - 10V
• 0 - 20 mA
Signal input (
ANALOG _ IN)
:
ANALOG_IN
LOGIC_GND
ADC
10 k
Ω
Potentiometer
+5V