49
Supply Voltage VDC Connection
IMS-MN-LMDA42C_A.pdf
LMD CANopen
Pin
MD-CS620 Wire
Signal
Function
1
Brown
VDC
Supply voltage
2
White
0 VDC
Reference potential to VDC
3
Blue
AUX
+12 to +24V Auxiliary Power
4
Black
0 VDC
Reference potential to VDC
Connector Style
: 4-position M12 (male) B-Coded
Recommended cable/cordset
: M12 Power Cable - Straight, 9.8 ft(3m) length, flying leads to 4-position
M12 (female) B-Coded (IMS part number - MD-CS620-000)
Wiring/cable Specifications
Use shielded twisted pair cabling for the supply voltage
VDC
.
• Verify that wiring, cables, and connected interfaces meet the protected extra-low voltage
(PELV) requirements.
• Ensure that the wiring conforms to the specified technical data.
• Conform to the information provided in the section “External Power Supply Units” on page
36 and “Ground (Earth) Design” on page 40.
• Install fuses for the power supply cable in accordance with the electrical requirements of the
equipment (note the inrush currents).
System EMI performance may be impacted by the wire size, length, and current. For wire size
requirements, refer to the
table on page 38.