28
IMS-MN-LMDA42C_A.pdf
Mechanical Data
LMD CANopen
Foot Mounts
The following graphic shows the dimensions for the LMD electric cylinder with the foot
mounting option.
1.45 (36.8)
3.45
(87.6)
2.56 (65.0) max
3.22 (81.8) max
0.19
(4.8)
1.83 (46.5) + Stroke Length
5.55 (140.9) max + Stroke Length
0.19
(4.8)
M10 x 1.25
THREAD
0.87
(22.0)
1.38 (35.0)
0.49
(12.5)
1.38 (35.0)
Stroke Lengths may range from
2.0 (51) min. to 18.0 (457) max.
0.55
(13.9)
2.06 (52.3)
1.67 (42.4)
2.13
(54.1)
3.67
(93.1)
2.05 (52.1)
1.29
(32.77)
1.067
(27.1)
LMAX2
= Stroke Length + 2.16” (54.86 mm)
LMAX2 - 0.879 (22.33)
1.500
(38.10)
4x Ø 0.217
(5.51) THRU
24.0 (610) max stroke length
Motor Stack Length
L
MAX
1
L
MAX
2
Single
in (mm)
SL + 5.5” (141 mm)
SL + 1.83” (46.5 mm)
SL = Stroke length (2.0” to 18.0” in 0.01” increments