OWN-ADV 01/12
9.3 REGISTER MAP (CONT’D)
62
51 EMERGENCY STOP
54 MAINTAIN NEEDED
55 INITIALIZING
56 MAINTAINED
62 LOG CORRUPTED
63 MODBUS START
162 (0xA2) CONFIG FAIL 1
163 (0xA3) CONFIG FAIL 2
233 (0xE9) DTC
40132
Log Time stamp
Minutes
Decimal
0 ~ 59
R
Decimal format
High 4-bit tens 0 ~ 5
Low 4-bit ones 0 ~ 9
Minute
40133
Log Time stamp
Hours
Decimal
0 ~ 23
Decimal format
High 4-bit tens 0 ~ 2
Low 4-bit ones 0 ~ 9
Hour
40134
Log Time stamp
Date
Decimal
1 ~ 31
Decimal format
High 4-bit tens 0 ~ 3
Low 4-bit ones 0 ~ 9
Day
40135
Log Time Stamp
Month
Decimal
1 ~ 12
Decimal format
High 4-bit tens 0 ~ 1
Low 4-bit ones 0 ~ 9
40136
Log DTC code.
Only valid if entry
contains DTC mes-
sage (if Log Type
register – 40131
equals 233).
0 ~ 255
R
Lowest byte of SPN (bit 8 MSB)
40137
0 ~ 39
Middle byte of SPN (bit 8 MSB)
40138
0 ~ 31
3 highest bits of SPN and the FMI (bit 8
is SPN MSB and bit 5 is FMI MSB)
40139
Bit 8 CM, other 7 bits OC (bit 7 MSB)
40140
Log Sequence
1 ~ 100
R
Current log being read.
40141
Total Log Number
1 ~ 100
R
Total number of entries in the log.
10: APPENDIX C: NMEA2000 PGN’S
Note: In this document, all de
fi
nition of the bytes and bits, the
fi
rst byte and
fi
rst bit always start from
1. All standard PGN can
fi
nd its de
fi
nition in NMEA2000
fi
les.
The WaveNet and WaveNet remote support the PGNs given in the following sections.