75
Fault
Diagnosis
Remedy
The grippers do not
open.
The display shows:
Error Motor D
Error Motor L
Error Cover
The machine cannot
be turned ON.
The stripping operation
is not properly per-
formed or the cycle
cannot be started.
Please check.............
if the grippers have been properly
adjusted.
overload when wire cutting starts.
overload due to debris in the strip-
ping head.
overload because of stripping slugs
blocking the stripping head.
overload due to faulty assembly
after cleaning or replacing the strip-
ping blades.
overload during stripping
if the safety cover is installed.
the fuses.
An incorrect voltage has been se-
lected.
Center the grippers again (page 37).
Check programming by pressing the
F
key.
Clean the stripping head (page 44).
Remove stripping slugs and clean the
stripping head if necessary (page 44).
Check assembly after cleaning or re-
placement of blades (page 28 and 44).
Divide the stripping length into several
steps (page 15).
Install the safety cover and make sure
it is correctly positioned. Tighten
screws (page 11).
Replace the fuses (page 12).
Set voltage selector to the desired
mains voltage (page 12)