conductors pressed
into the dielectric of
the shield.
insulation is cut on one
side only.
the symmetrical arrangement of the
centralizers and stripping blades.
if the stripping blades are sharp and
have no signs of chipped edges.
if one or both stripping blades is out
of position.
the cable for eccentricity or if there
are irregularities.
Use eccentric to adjust the position of
the centralizers.
Replace stripping blades (page 28).
Center the stripping blades correctly
(page 28).
Contact the wire supplier.
Fault
Diagnosis
Remedy
The stripping opera-
tion cannot be started.
The trigger contact
moves back slowly or
not at all.
The contact force is
insufficient.
The grippers do not
hold the cable secure-
ly.
Please check.............
if the trigger contact can be moved
freely.
the centricity of the module in rela-
tion to the axis.
whether the release rod is impaired
by grease, oil or stripping slugs.
whether the release contact spring
is in place and has been properly
tensioned.
whether the tension of the release
contact spring is adequate.
if the grippers are dirty.
if stripping slugs interfere with the
clamping movement.
if the magnet functions correctly.
if the tension spring has been
properly tensioned.
Readjust the trigger contact (page 40).
Readjust the trigger contact (page 40).
Clean the release rod.
Mount the spring or shorten/tighten the
spring.
Tighten the spring of the release con-
tact.
Clean the grippers (page 44).
Clean the grippers (page 44).
Replace the magnet’s printed circuit
board.
Shift magnet in direction
B
or replace
the tension spring (page 42).