Place brass sleeve (32) with a diameter of 5.2 mm
onto the adjusting pin of the calibration kit (Fig. 24).
•
Loosen gripper mounting screws (33) and gripper
holder screws (34) slightly (Fig. 24).
•
Pull plunger (35) of the magnet 36) to the rear.
•
Place the 8 mm wide spacer (39) between toggle levers
(37) and follower (38) (Fig. 25).
•
Carefully pull the stripping head (5) fully forward by hand (Fig.
26).
•
Slightly press the two grippers (4) against the brass sleeve (32)
of the calibration kit on both sides and firmly tighten the gripper
mounting screws (33) defining the height of the centering (Fig.
26).
•
Check again and make sure the stripping head is in its fully for-
ward position.
Fig. 24. Brass sleeve, 5.2 mm
Fig. 25. Insert spacer
Fig. 26. Centering the grippers