Electrical and Control System
61
Service Manual – SW900
Dynamotor Voltage Check (SW900 P)
Warning!
This procedure must be
performed by qualified
personnel only.
1
Drive the machine on a level floor and ensure
that it cannot move
2 Turn the ignition key to “0”
3 Remove the hopper by using its transport handle
and wheels
4
Carefully operate and keep operated, the hopper
position microswitch (to simulate the presence of
the hopper)
5 Check that the main and side brooms(s) are
lifted
6 Turn the ignition key to “I” and start the petrol
engine (as shown in the
User Manual); wait
at least 5 minutes that the engine reaches the
target speed
7 Disengage the front fastener and o
pen the
engine compartment hood
8 Move aside the guards (A) of the terminals (B)
and (C) of the dynamotor (D)
9 Apply the detectors (E) and (F) of the tester
on the terminals (B) and (C) and measure the
voltage produced by the dynamotor, which must
be between the 12V and 14V
Stop the petrol engine (as shown in the User
Manual)
Turn the ignition key to “0”
P200282
Summary of Contents for SW900
Page 13: ...General Information 13 Service Manual SW900 Machine Nomenclature SW900 B Continues P200252 ...
Page 14: ...General Information 14 Service Manual SW900 Machine Nomenclature SW900 B Continues P200253 ...
Page 15: ...General Information 15 Service Manual SW900 Machine Nomenclature SW900 B Continues P200254 ...
Page 17: ...General Information 17 Service Manual SW900 Machine Nomenclature SW900 P Continues P200256 ...
Page 18: ...General Information 18 Service Manual SW900 Machine Nomenclature SW900 P Continues P200257 ...
Page 19: ...General Information 19 Service Manual SW900 Machine Nomenclature SW900 P Continues P200258 ...
Page 23: ...General Information 23 Service Manual SW900 Dimensions P200259 ...