Electrical and Control System
51
Service Manual – SW900
Fuse Check/Replacement/Reset (SW900 B)
1
Drive the machine on a level floor and ensure
that it cannot move
2 Turn the ignition key to “0”
Fuse Check/Reset
3
Check one of the following fuses for deactivation:
-
(A): 70A fuse (FA), main motor
-
(B): 5A fuse (FB), right side broom motor
-
(C): 5A fuse (FC), left side broom motor
4
Reset any deactivated fuse, when the component
that caused deactivation has fully cooled down
Various Fuse Check/Replacement
5 Remove the hopper by using its transport handle
and wheels
6 Disengage the front fastener and open the
battery compartment hood
7 Disconnect the battery connector
8 Remove the rear grid after removing the upper
mounting screw and disengaging the fasteners
9
Disengage and open the cover (I), then check the
fuse:
-
(J): 30A fuse (F2), battery charger
-
If necessary, remove the nuts (D) and replace
the fuse (J) Screw down and tighten the
nuts
P200277
Summary of Contents for SW900
Page 13: ...General Information 13 Service Manual SW900 Machine Nomenclature SW900 B Continues P200252 ...
Page 14: ...General Information 14 Service Manual SW900 Machine Nomenclature SW900 B Continues P200253 ...
Page 15: ...General Information 15 Service Manual SW900 Machine Nomenclature SW900 B Continues P200254 ...
Page 17: ...General Information 17 Service Manual SW900 Machine Nomenclature SW900 P Continues P200256 ...
Page 18: ...General Information 18 Service Manual SW900 Machine Nomenclature SW900 P Continues P200257 ...
Page 19: ...General Information 19 Service Manual SW900 Machine Nomenclature SW900 P Continues P200258 ...
Page 23: ...General Information 23 Service Manual SW900 Dimensions P200259 ...