Dynamotor Voltage Check (SW900 P) (Continues)
If the voltage is lower than the specified value,
perform the following procedures to detect the
cause and correct it:
•
Check that the drive belt between the
engine and reduction unit is properly ten-
sioned (see the procedure in the relevant
paragraph) and that the pulleys are efficient
and not loose
•
Check that the reduction unit is correctly
closed
•
Check the dynamotor carbon brushes (see
the procedure in the relevant paragraph)
• If necessary, disassemble the dynamotor
(see the procedure in the relevant para-
graph), and check the condition of all its
components
If the above-mentioned procedures do not lead
to a correct voltage, the dynamotor must be
replaced (see the procedure in the relevant
paragraph)
Reassembly
10 Close the engine compartment hood and engage
the front fastener
11 Release the hopper position microswitch
from the forced operation, and check that the
microswitch operates properly
12 Install the hopper by using its transport handle
and wheels
Summary of Contents for SW900
Page 13: ...General Information 13 Service Manual SW900 Machine Nomenclature SW900 B Continues P200252 ...
Page 14: ...General Information 14 Service Manual SW900 Machine Nomenclature SW900 B Continues P200253 ...
Page 15: ...General Information 15 Service Manual SW900 Machine Nomenclature SW900 B Continues P200254 ...
Page 17: ...General Information 17 Service Manual SW900 Machine Nomenclature SW900 P Continues P200256 ...
Page 18: ...General Information 18 Service Manual SW900 Machine Nomenclature SW900 P Continues P200257 ...
Page 19: ...General Information 19 Service Manual SW900 Machine Nomenclature SW900 P Continues P200258 ...
Page 23: ...General Information 23 Service Manual SW900 Dimensions P200259 ...