background image

INC

JAA79551-R.3690.A

- A 0・AF-S VR 70-300/4.5-5.6G -

 Mount the main base plate unit on the rear fixed tube, and fix them with the spring washer (#138) and the 

screw (#139).

 Connect each FPC to the appropriate connector of 

the main base plate unit.

#138

#139

Attach the SWM FPC on the rear fixed tube.  

(SWM FPC has the adhesive double-coated tape 

attached.)

Main base plate unit

Main base plate unit

Rear fixed-tube

Distance-FPC

Zoom FPC

VCM relay-FPC

GMR FPC

SWM FPC

Gyro-FPC

PSD relay-FPC

Contacts unit

 Adhesive: Screw lock

Summary of Contents for JAA79551

Page 1: ... 配布許可印 JAA79551 R 3690 A Copyrigh c 2006 by Nikon Corporation All Rights Reserved 無断転載を禁ず Printed in Japan October 2006 M サービス 計画課 AF S VR ZOOM NIKKOR ED 70 300 f4 5 5 6G JAA79551 MADE IN THAILAND REPAIR MANUAL ...

Page 2: ...ernal Focusing IF system utilizing an internal Silent Wave Motor manually via separate focus ring Vibration reduction Lens shift method using voice coil motors VCMs Shooting distance scale Graduated in meters and feet from 1 5m 5 ft to infinity Closest focus distance 1 5m 4 9 ft at all zoom settings No of diaphragm blades 9 pcs rounded Diaphragm Fully automatic Aperture range f 4 5 to f 32 at 70mm...

Page 3: ...e solder and lead solder They cannot be used in common Points to notice for Lead free solder products Whenever the 2nd lens group unit of this lens is removed replace it with the new 2nd lens G holding tube of RP After reassembly the optical lens alignment work becomes necessary At service facilities where such work cannot be carried out do NOT remove the 2nd lens group unit On this lens the VR vi...

Page 4: ...INC JAA79551 R 3690 A D AF S VR 70 300 4 5 5 6G 92 3 1 Disassembly Rear cover ring Rear cover ring G1 unit 82 G1 unit ...

Page 5: ...ring to TELE 300 then insert the two infinity pins J11339 to the two holes G2 G3 unit 2nd lens group unit Remove the hole cover sheet Zoom rubber Zoom rubber Hole cover sheet New tool Infinity pin J11339 2 Caution When the hole cover sheet is removed be careful NOT to damage the lens ...

Page 6: ...up Take out three screws 110 and remove the 2nd lens group 110 3 133 62 A H Caution 1 Whenever the 2nd lens group is removed optical alignment work becomes necessary after reassembling Therefore at service facilities where this work cannot be performed do NOT remove the 2nd lens group Caution 2 Whenever the 2nd lens group is removed replace it with the new 2nd lens G holding tube refer to page D20...

Page 7: ...AA79551 R 3690 A D AF S VR 70 300 4 5 5 6G 125 2 65 125 2 65 126 126 Zoom coupling lever Peel off the two cover sheets 126 Take out four screws 125 and remove the two zoom coupling levers 65 Zoom cover ring ...

Page 8: ...s body Zoom ring Remove the zoom ring from the zoom cover ring Peel off the three pieces of the fixing tape 111 Zoom ring Rotate the zoom ring until its 300 mark is positioned approx 1 cm away from the zoom index Then remove the zoom ring from the lens body 111 3 Zoom cover ring ...

Page 9: ... VR 70 300 4 5 5 6G 103 90 90 Contacts unit Take out two screws 90 and remove the contact unit Contacts unit Slack of Change SW unit Take out the screw 103 of the change SW unit and leave the unit slightly slackened Change SW unit ...

Page 10: ...690 A D AF S VR 70 300 4 5 5 6G 92 3 93 97 2 84 83 A I 96 23 94 95 28 30 25 Take out the three screws 93 and one screw 93 and remove the bayonet mount Remove the washer 83 selected from A I Bayonet mount Bayonet mount ...

Page 11: ...ns body Caution Do not lift up the mount fixed tube strongly Otherwise change SW FPC will be cut off Hole of mount fixed tube Remove the name plate and focusing index window from the mount fixed tube Caution This removal is NOT necessary except replacing any of the below two parts Focusing index window Name plate Mount fixed tube Change SW unit Lens body ...

Page 12: ...in base plate unit Zoom FPC VCM relay FPC GMR FPC SWM FPC Gyro FPC PSD relay FPC Contacts unit Remove SWM FPC from the rear fixed tube Caution Removing the contacts unit is NOT necessary except replacing it Remove the spring washer 138 and the screw 139 Then remove the main PCB from the rear fixed tube Main base plate unit Rear fixed tube ...

Page 13: ...he FPC of the change SW unit from the connector of the main base plate unit Change SW unit Change SW unit Main base plate unit Rear fixed tube Take out two screws 106 and the screw 116 Then remove the rear fixed tube from the front fixed tube Rear fixed tube Front fixed tube ...

Page 14: ...51 R 3690 A D 12 AF S VR 70 300 4 5 5 6G Gyro FPC Rear fixed tube Gyro FPC Remove the gyro FPC from the rear fixed tube VCM relay FPC PSD relay FPC Remove the FPCs from each connector VCM relay FPC PSD relay FPC ...

Page 15: ...s 136 Then remove each FPC from the front fixed tube VCM relay FPC Front fixed tube PSD relay FPC Front fixed tube Hold the VCM relay FPC and PSD relay FPC with tweezers Then slide and remove them from the FPC fixing plate VCM relay FPC PSD relay FPC FPC fixing plate FPC fixing plate ...

Page 16: ... the focus ring unit and align with the index Remove the focus ring unit from the lens body Focus ring unit Take out three screws 121 and remove the SWM unit from the front fixed tube Be careful NOT to touch the metal area directly by hand SWM unit Front fixed tube SWM unit Metal area Index ...

Page 17: ... Remove the two pieces of the protection tape TA 0012 2 and peel off the focus index sticker from the SWM unit 140 4 SWM unit Focus index sticker TA 0012 TA 0012 Be careful NOT to touch the MR head when the zoom ring unit is removed SWM Zoom ring unit Metal area MR head Be careful NOT to touch the metal area of the SWM ...

Page 18: ...F S VR 70 300 4 5 5 6G Take out two screws 541 and remove the GMR unit and 534 534 541 2 Take out the screw 543 and remove the MR retaining springs 533 and 536 501 Remove the FPC of GMR unit from 501 533 536 543 GMR unit GMR unit ...

Page 19: ...out three screws 544 and remove 537 from the SWM Remove the MR ring unit from the SWM 544 3 537 MR ring unit Be careful NOT to touch the MR tape directly by hand MR tape SWM Take out three screws 73 from the 1st lens G tube 1st lens group tube 1st lens group tube ...

Page 20: ... 121 and remove the 1st lens G tube 1st lens group tube Remove the three nuts 74 three rollers 76 selected from A to D and three rollers 75 selected from A to D from the cam groove of the front fixed tube Front fixed tube 145 A 2 Caution The two washers 145A are attached at the positions of the picture ...

Page 21: ... 6 78 A G 6 Lead groove ring Front fixed tube Take out six screws 77 and remove six rollers 78 selected from A to G and six rollers 79 selected from A to G from the cam groove of the front fixed tube Remove the front fixed tube from the body Front fixed tube Body ...

Page 22: ...holding tube unit and 2nd lens G holding tube 3rd lens group holding tube unit 3rd lens G holding tube unit 2nd lens G holding tube Rotary tube Peel off the light shielding sheets 141 and 142 from the lead groove ring Lead groove ring Caution Whenever the 2nd lens group is removed replace it with the new 2nd lens G holding tube which is prepared as RP ...

Page 23: ...hree rollers 81 selected from E to I and three rollers 80 selected from E to F from the screw holes of the rotary tube Hole of rotary tube Remove the focus tube unit and rotary tube from the lead groove ring Rotary tube Lead groove ring Focus tube unit Focus tube unit Caution Remove the screw 71 while holding the focus tube unit ...

Page 24: ...0 300 4 5 5 6G 105 104 125 2 64 Zoom brush Take out the screw 105 and remove the zoom encoder brush 104 from the cam ring Cam ring Cam ring Zoom control lever Take out two screws 125 and remove the zoom control lever 64 from the cam ring ...

Page 25: ...g from the front fixed tube Peel off the zoom FPC 1006 from the front fixed tube Caution In case a proper combination between the cam ring and front fixed tube is not made optical performance may be less Therefore even if only either of them is replaced be sure to use the combined unit which is provided by RP ...

Page 26: ...INC JAA79551 R 3690 A D 24 AF S VR 70 300 4 5 5 6G Remove 144 from the 3rd lens G holding tube unit 144 134 Peel off 134 from the 3rd lens G unit 3rd lens G unit 3rd lens G holding tube unit ...

Page 27: ...e the spring 38 from the spring hook Release the hook from the 3rd lens group unit and remove the aperture blade base cover Fig 1 Caution 1 The 3rd lens G unit is optically aligned by using a special equipment Therefore in case a further disassembly is necessary replace with the 3rd lens G unit of repair parts RPs Caution 2 VR unit is assembled in the 3rd lens G unit Aperture blade base cover Blad...

Page 28: ...tout Fit the protrusion of the aperture blade base cover in the cutout of the blade actuating plate 3rd lens group unit Aperture blade unit 3rd lens G unit Spring 38 Blade actuating plate Spring hook Blade actuating plate Aperture blade unit 9 Aperture blade base cover Blade actuating plate ...

Page 29: ...rd lens G unit 134 has the adhesive double coated tape attached 134 When attaching 144 give the same roundness as the outer circumpherence of the 3rd lens G holding tube unit Caution Without the roundness when attaching 144 it will interfere with the aperture coupling lever causing an unsmooth movement Aperture coupling lever 3rd lens G unit 3rd lens G holding tube unit ...

Page 30: ...ouble coated tape attached Folding position 1006 56 Reference position for attachment Grease GN 20S Apply to the 6 straight grooves Grease GN 20S Apply to the overall sliding surface Grease GN 20S Apply to the overall sliding surface Grease NKS 211SP Apply thinly to the overall zoom encoder pattern Adhesive C 8008B Apply to the edge face of FPC zoom FPC 1006 ...

Page 31: ... the front fixed tube Fig 2 125 2 64 Grease GN 20S Apply to 9 grooves Cutout Cutout Protrusion Fig 1 Fig 2 Fig 3 Cam ring Cam ring Front fixed tube Attach the zoom control lever 64 to the cam ring and fix it with two screws 125 Fig 3 Caution In case a proper combination between the cam ring and front fixed tube is not made optical performance may be less Therefore even if only either of them is re...

Page 32: ... direction of the arrow A rotate the cam ring all the way to WIDE end Loosen the screw 105 and adjust the brush position so that the points of the brush are placed as shown in Fig 1 Tighten the screw 105 and fix it with Screw lock Fig 1 105 104 Adhesive Screw lock A Zoom brush Cam ring Adjustment position of Zoom brush ...

Page 33: ...ers 80 selected from E F then fix each pair with the screw 71 at three places Grease F 890 Apply to the overall sliding surface with the focus tube unit Apply to the overall sliding surface with the front fixed tube 56 Apply to the overall sliding surface with the lead groove ring Grease F 890 Grease F 890 Caution Select the roller 81 from E to I according to the width of the groove of the lead gr...

Page 34: ... 2nd lens G holding tube to come to the cutout side of the lead groove ring Then lift and slide only the rotary tube and mount the 2nd lens G holding tube by fitting its three projections in the three straight grooves of the lead groove ring While lift and slide only the rotary tube mount the 3rd lens G holding unit by fitting its three projections in the three straight grooves of the lead groove ...

Page 35: ... of the arrow shown in Fig 2 and align the cutout with the connector Fig 2 Put the roller 78 selected from A G and the roller 79 selected from A G at six places then fix these with the screw 77 through the cam groove at six places Fig 3 Cutout 79A G 6 78A G 6 Cutout Connector Fig 1 Fig 2 Fig 3 Cutout Mounting of Front fixed tube Front fixed tube Lead groove ring 3rd lens G holding tube unit ...

Page 36: ...e nut 74 at three places Remove the body from the lens stand J11338 Apply to the overall contacting surface with the cam ring 1st lens group tube 74 3 76 A D 3 75 A D 3 Caution Align the direction of the nut and reference lines as below Then push the nut 74 all the way seated at three places 74 Cutout of the lead groove ring Index Grease MZ 800S Adhesive Lock end B Mounting of 1st lens group tube ...

Page 37: ...37 on the SWM and fix it with the three screws 544 SWM unit Focus coupling key 544 3 537 Cutout 1st lens G tube Confirm that the nut 74 is NOT inserted sideways at three places Slide the 1st lens G tube and confirm that there is neither any irregularity nor catch in zoom operations Be careful NOT to touch the MR tape area directly by hand MR tape Be careful NOT to touch the metal area of the SWM M...

Page 38: ...g screws 541 534 541 2 Fix the MR holddown spring 533 and 536 with the screw 543 Caution Adhere the FPC of the GMR unit without any sag GMR unit 501 Attach the FPC of the GMR unit on 501 with the adhesive double coated tape which is already adhered inside 501 533 536 543 GMR unit Magnetic tape ...

Page 39: ... voltage power supply 1 unit 5V 100mA Oscilloscope 1 unit Self made tool 1 unit Caution If there is a problem with continuity between the contacts of the self made tool and the relay FPC the contacting surface of the relay FPC may be dirty eroded or oxidized So polish the contacts and connect them 2 Preparation of the lens for measurement Assemble the MR head attached zoom index ring unit the SWM ...

Page 40: ...d from touching the magnetized driver bit Otherwise the magnetic data may be damaged 541 2 MR head GMR unit Oscilloscope setting V Div ch1 50 mV V Div ch2 50 mV Coupling AC Time Div 2 m Sec Trigger Mode NORMAL Trigger Coupling AC Amplitude Fig 1 Standard Amplitude of all pulses wave forms is 80mV or more Note Check the waveform by moving the focus ring back and forth from the infinity end to the c...

Page 41: ...the 2 screws 541 may be loosened so check for it If this is not the case the MR head may malfunction so replace the GMR unit and make a readjustment As shown in Fig 2 if the amplitude partially drops between the infinity and the close distance the magnetic data of the tape may be damaged So replace the MR ring unit and make a readjustment Replacing only the magnetic surface is impossible Fig 2 ...

Page 42: ...he adhesive double coated tape attached SWM 140 4 Zoom ring unit Align the position of the protrusion with the cutout of the distance scale sticker Fit the projected part of the distance scale sticker in the groove of the SWM Distance scale tape SWM Index MR head TA 0012 TA 0012 Caution Whenever the zoom ring unit is mounted do NOT touch the MR head Grease OS 30MF Apply to the overall surface of t...

Page 43: ...mbled unit until infinity end position After assembling the SWM assembled unit into the front fixed tube rotate the focus ring unit and check that the distance scale can move therewith Fig 2 Tighten three screws 121 Index Protrusion Groove Grease MZ 800S Apply to the sliding surface with the lens body Caution When the SWM assembled unit is mounted do NOT let the MR head touch the front fixed tube ...

Page 44: ...sliding the FPC from the side into the FPC fixing plate Attach each FPC to the front fixed tube and tighten the four screws 136 FPC fixing plate FPC fixing plate Caution Do NOT scratch the FPC by catching the edge corner of the FPC fixing plate 136 2 136 2 Adhesive Screw lock A part A part VCM relay FPC PSD relay FPC VCM relay FPC PSD relay FPC VCM relay FPC Front fixed tube PSD relay FPC Front fi...

Page 45: ...be by lining up the center positions of the cutout A part and the gyro FPC as below Gyro FPC has the adhesive double coated tape attached A part Connect the VCM relay FPC to the connector Connect the PSD relay FPC to the connector VCM relay FPC PSD relay FPC Gyro FPC Gyro FPC Rear fixed tube ...

Page 46: ...16 Connect the FPC of the change SW unit to the connector of the main base plate unit Pass other FPCs than SWM FPC through the grooved part of the inside tube hole of the rear fixed tube Rear fixed tube Rear fixed tube Front fixed tube Change SW unit Change SW unit Main base plate unit 1 2 3 Caution Tighten the one screw 116 and two screws 106 in the order from 1 to 3 Adhesive Lock end B Adhesive ...

Page 47: ... screw 139 Connect each FPC to the appropriate connector of the main base plate unit 138 139 Attach the SWM FPC on the rear fixed tube SWM FPC has the adhesive double coated tape attached Main base plate unit Main base plate unit Rear fixed tube Distance FPC Zoom FPC VCM relay FPC GMR FPC SWM FPC Gyro FPC PSD relay FPC Contacts unit Adhesive Screw lock ...

Page 48: ...plate have the adhesive double coated tape attached Pass the change SW unit of the lens body through the hole of the mount fixed tube and assemble them Align the indexes Grease MZ 800S Apply to the overall sliding surface with the focus ring unit Mount fixed tube Focusing index window Name plate Mount fixed tube Hole of mount fixed tube Change SW unit Lens body ...

Page 49: ...70 300 4 5 5 6G Put the washer 83 selected from A to I by aligning the holes Mount the bayonet mount and fix it with the three screws 92 and one screw 93 92 3 93 97 2 84 83A I 96 23 94 95 28 30 25 Grease I 40 Bayonet mount Bayonet mount ...

Page 50: ... R 3690 A A 23 AF S VR 70 300 4 5 5 6G Fix the change SW unit with the screw 103 103 Fix the contacts unit with two screws 90 90 90 Change SW unit Change SW unit Temporary attachment of Contacts unit Contacts unit ...

Page 51: ...Mount the zoom ring on the zoom cover ring by aligning the cutout of the zoom ring with the projected part of the zoom cover ring Zoom ring Attach three pieces of the fixing tape 111 Zoom ring Zoom cover ring Zoom cover ring Cutout Projected part 111 3 ...

Page 52: ...e two cover sheets 126 125 2 65 125 2 65 126 126 Adhesive Screw lock Align the position of 300 mark approx 1 cm away to the right from the zoom index Then assemble the zoom ring into the lens body and rotate in the direction of the arrow A Index A Grease MZ 800S Apply to the overall sliding surface with the zoom ring unit Grease GP 1RS Apply to the overall groove of the zoom ring unit Lens body Zo...

Page 53: ...om to TELE end 300 Then insert the two infinity pins J11339 in the two holes as shown in Fig 1 Fig 1 Fix the 2nd lens group unit with three screws 110 Attach the cover sheet 133 2nd lens G unit 110 3 133 2nd lens group unit G2 G3 unit Infinity pin J11339 2 New tool Adhesive Screw lock ...

Page 54: ...the G2 G3 unit G2 G3 unit 62 A H G2 G3 unit assembling tool J11337 New tool Pin 2 Put the washer 62 selected from A to H Then fit the two pin parts of the G2 G3 assembling tool J11337 into the two holes of the G2 G3 unit and assemble them into the body Remove the two pins J11339 that were inserted in ...

Page 55: ...INC JAA79551 R 3690 A A 28 AF S VR 70 300 4 5 5 6G 82 Caution Attach the sheet 82 after completing the FFD adjustment G1 unit G1 unit ...

Page 56: ... the above requirements are met either desktop or notebook PC is available Preparation for inspection adjustment of main PCB In case of replacing the main PCB SWM unit or MR encoder unit be sure to make the necessary adjustments as follows 1 Adjustments Adjust the MR duty Adjust the driving frequency and motor control including Focus preset adjustment 2 Equipment and tools to be required Single ou...

Page 57: ...ation When the RS232C terminal of the personal computer is a 9 pin type connect it by using the 25 pin 9 pin conversion connector RJ does not supply this connector Use products on the market Personal computer This system does not depend on the CPU type of personal computer AF I communication adapter J15307 To RS232C terminal AF I communication box J15306 1 Oscilloscope Power supply 6V New tool ...

Page 58: ... on the screen rotate the MF ring slowly by hand in the direction from the infinity to the close distance position Make sure that the waveform on the oscilloscope has duty 50 and stop the MF ring at the close distance end Setting of oscilloscope V Div CH1 5V V Div CH2 5V Coupling DC Time Div 5 m Sec Trigger Mode NORMAL Trigger Coupling DC Trigger Source CH 1 Trigger Position 4 div Trigger Type EDG...

Page 59: ...voltage power supply ON Select 2 Adjustment for Frequency and Control in the menu of the AF S VR70 300 inspection program The lens automatically starts the driving of scanning Fig 2 When the above Fig 1 is displayed select OK to complete the adjustment of Driving frequency and Motor control When the above Fig 2 Adjustment could not be execute is displayed make adjustments again In case the above F...

Page 60: ...rity of mechanical operations does not take place in the focus ring driving unit the servo time tends to be long if it is heavy in the cam ring rotation of the MR encoder while the servo time tends to be short if it is light in its rotation of the MR encoder 4 Switches and lenses Check the ON OFF operations of switches and the operating condition of the distance encoder After inspections 1 When th...

Page 61: ...ing up all the data on EEPROM value in the lens and for writing the backuped files into the lens This is not used for regular repairs The items 4 7 are used for inspections Selection items After selecting items screens appear such as the lens selection the focal length selection the voltage set ting the inspection mode start The screens depend on the items Follow the instructions of the personal c...

Page 62: ...If the MF ring is rotated while the lens scanning is driven the pulse shows an abnormal value Do NOT touch the MF ring during operations When the inspection ends the result of the next page appears Make this inspection on both focal length 70mm W and 300mm T Select the focal length to be inspected ...

Page 63: ...INC JAA79551 R 3690 A A36 AF S VR 70 300 4 5 5 6G Total number of pulses when inspected must be within standard Standard Total pulses 6801 204 PULSE S ...

Page 64: ...the delay time msec millisecond which prevents stopping the lens Fig 3 3 Inspection of lens servo stop accuracy Note The value of ADUST DELAY TIME is set by the adjustment software So if the lens does not stop during the inspection of LENS DRIVING STOP ACCURACY any value can be input without problem However the larger the value of ADJUST DELAY TIME gets the longer the inspection time becomes input...

Page 65: ... pulses must be within the standards after the lens back and forth driving 5 motion 5 5TIME S in of the display Standard RATIO 1 is 40 or less for Df1 Df6 of the screen Occurrence ratio of 6 15 pulses RATIO 2 is 10 or less for Df1 Df6 of the screen Occurrence ratio of 11 15 pulses Occurrence of 16 or more pulses is zero for Df1 Df6 of the screen Only one occurrence indicates defective Df1 Df6 show...

Page 66: ...mal value Do NOT touch the MF ring during inspections This inspection must be made at the following 5 lens positions with the focal length both 70 mm W and 300 mm T Oscilloscope setting V Div 5V Coupling DC Time Div 20 m Sec Trigger Mode SGL S Trigger Coupling DC Trigger Source CH1 Trigger Position 4div The waveforms of E and H terminals have the forms for going up for start and going down for sta...

Page 67: ...gnals of the distance encoder The value changes by turning the MF ring with M or M A of the lens driving mode selector Position of the zoom encoder Value changes by turning the zoom ring The status of Switches 5 Inspection of switches and lens conditions ...

Page 68: ...ncoder operations lens servo stop accuracy lens servo time switches lens condition VR adjustment Aberration compensation data writing adjustment including aberration compensation inspection Main PCB unit SWM unit 3rd lens group unit GYRO FPC unit GMR unit Front fixed tube G1 lens unit G2 G3 lens unit 2nd lens group unit Necessary adjustment when replacing parts Parts to be replaced Adjustments ...

Page 69: ... computer Mount the lens on the equipment Set the focus ring to the infinity position and the zoom ring to TELE side Please refer to the next page for the procedure to mount the lens WARNING This equipment uses the laser beam Do not look into the laser beam directory Notes The distance from the laser beam outgoing port to the radiation face should be about 5m apart Do not intercept the optical pat...

Page 70: ...rocedure to mount the lens 1 Attach the lens to the equipment and move the lens retainer stand in the direction of the arrow 2 Move the lens retainer stand to the position shown in Figure below and fix it by tightening the clamp Lens retainer stand Clamp ...

Page 71: ...k it If the below mesage appears set the zoom ring again by referring to the pre page Procedure to mount the lens and click the OK button The focus ring is automatically set Notes Do not change the lens settings zoom ring until the adjustment is finished and it goes back to the Lens Selection window If the setting position changes in the middle of the adjustment the correct adjustment value cannot...

Page 72: ...00 4 5 5 6G Move the cursor to a box in front of the VR Switch Inspection and click to mark the check marking Move the cursor to the Execute button and click it VIBRATION REDUCTION MODE SW INSPECTION VR Mode Switch Inspection window is shown ...

Page 73: ...e position of VR mode switch is indicated By turning the VR mode switch the current position is shown in the real time When finishing the VR mode switch move the cursor to the Exit button and click it to evacuate from the inspection window VR mode switch ...

Page 74: ...wn Set the VR mode switch of the lens to ON Full or Release and then move the cursor to the OK button and click it VCM Polarity Adjustment Controlled automatically Detect the polarity of the VCM Voice Coil Motor and write it in EEPROM as the compensation value In between times the message to confirm the lens position of angle 0 or 90degrees appears So set the lens to the position and click the OK ...

Page 75: ...s the message to confirm the lens position of angle 0 or 90degrees appears So set the lens to the position and click the OK button When OK is shown on the window move the cursor to the Next button and click it When the message that says rewriting the checksum is finished is shown click the OK button Then set the VR mode to OFF according to the message and click the OK button to evacuate from the a...

Page 76: ...to mark the check marking Move the cursor to the Execute button and click it The message like a picture on the left is shown Set it to the Telephoto settings Loosen the nut of the laser switch of the VR lens adjustment equipment J15380 and rotate the screw in an arrow direction to give the laser Laser beam pointer Laser switch Nut Top view ...

Page 77: ...the length of the vibration width a of the laser beam Notes The phenomenon that the laser spot light shakes up and down right and left occurs during measuring the vibration width This is the motion of the VR unit control and is not defective Move the cursor to the Next button in the message box on the screen and click it Vibration reduction function starts to perform and the vibration width of the...

Page 78: ...djustment button wait for a few seconds until a vibration motion is stabilized Buttons for Gyro Gain Adjustment Buttons for Angle Difference Adjustment Gyro Gain Adjustment Adjust the vibration width by the button for Gyro Gain Adjustment so that the length of the vibration width becomes be less than 1 5 of the measured laser vibration width a Standard Less than 1 5 of the vibration width a Notes ...

Page 79: ...in adjustment 40 1 5 8mm Center vibration width Whole vibration width becomes be 8 2 5 2 5 13mm How to obtain the minimum value of the vibration width Measure the vibration width while changing the adjustment value that is set every 0 02Step as shown below The peak section of the minimum vibration width can be obtained by the actual measured value Take the center of the peak section as the adjustm...

Page 80: ...ns Selection window Notes Do not remove the lens or turn OFF the VR lens adjustment equipment until it goes back to the Lens Selection window The trouble that the adjustment value is not stored correctly etc occurs since the communication is cut off Press STOP button of VIBRATION switch of the VR adjustment equipment to stop vibrations Rotate the lens through 90 in the direction indicated by the a...

Page 81: ...he noise of control Cause Defect of checksum Broken wire of the VCM Both sides Defect of the mode switch Others Countermeasure Perform the checksum with the equipment and then go to the Check 1 Confirm the breakage of the VCM and go to the Check 1 Perform the switch inspection with the equipment Go to Check 2 Cause Breakage of the VCM One side Adjustment value is abnormal Others Countermeasure Con...

Page 82: ...ation width How much does the vibration width reduce against those of when the VR mode is OFF and ON at the VR Gyro Adjustment Cause Adjustment value is not correct Others Countermeasure Perform the lens position adjustment and the VR gyro adjustment The electric parts other than VR might be defective The parts other than VR might be defective More than 1 5 Less than 1 5 ...

Page 83: ...while it is minus decrease the thickness of it Note When the washers 62 are put place a thin washer between thick washers Adjustment of F F D Back focus 1 Align mark of the focus ring with the index 2 Fix the aperture lever so that the aperture becomes wide open 3 Read the value of Wide or Tele side 4 Remove the bayonet mount 5 Adjust the washer 83 by increasing decreasing by the difference from t...

Page 84: ...e diameter Standard Full aperture In case the result is out of standard loosen the two adjustable screws 97 2 of the aperture lever and make an adjustment by moving 23 After the adjustment fix the two screws 97 2 with Screwlock J18004 1 97 2 23 Contact unit Fix the contact unit with the screw 90 2 90 90 contact unit Adhesive Screwlock ...

Page 85: ...R 70 300 4 5 5 6G Caution This adjustment is required when the 2nd lens group is removed Lens Alignment Chart shooting equipment for 2nd lens group alignment Slide rail for Lens alignment equipment The chart is embeddied in cardboards ...

Page 86: ...y mode to RAW WB to Preset and ISO to 200 Set up the camera D100 on a tripod on the slide rail Set the indication pointer of the tripod to 30 cm 30 cm Set the alignment chart J19128 as shown below Magnifications 30 Alignment chart J19128 Focal plane mark of camera Rail tool Front Back Turn the power of viewers 5 pcs to ON Note If the batteries of viewers are exhausted causing decreased brightness ...

Page 87: ...es position in the center of the viewfinder when the tripod is slid all the way to the front and back Connect the PC and camera via USB cable Camera setting Mass Storage Start the adjustment software AFS70_300 exe Lens Select window opens Select AF S VR70 300 4 5 5 6G then click OK button Click the Reset all log button Set the indication pointer of the tripod to 30 cm and set the focus mode switch...

Page 88: ...e chart by Focusing of the adjustment software and repeat 3 and 4 until the shape of point images become like Image 2 Adjustment location If the point image of the 1st or 2nd quadrant is blurred rotate the adjusting screw that can be seen through A hole of Fig 1 If the point image of the 3rd quadrant is blurred rotate the adjusting screw that can be seen through B hole of Fig 1 If the point image ...

Page 89: ...the measurement button of the adjustment software Ref Check Image 3 which was obtained by the chart shooting in the procedure of If the procedure is followed again here so that the shape of the point images at periphery becomes almost the same and the shape of those at center becomes also almost the same the overall operation time will be shorter Image 3 Point images at periphery Point images at c...

Page 90: ...make a remeasurement Repeat this operation four more times totalling in seven measurements The total sliding distance is 60 cm Note 1 When the below warning is given there may be some defects in the brightness of the viewers and or parallelism of the chart and camera etc So correct the above and make a remeasurement Note 2 When the below warning is given recheck that the Quality mode of the camera...

Page 91: ...n display shows END the lens optical alignment is completed If Information display shows Need Adjustment rotate the adjusting screw by approx 45 turn increments based on Reference on the next page If Check the 3rd LENS GROUP UNIT or other parts is shown check defects of the 3rd lens G unit or other light related parts and replace it them Confirmation screen Information display ...

Page 92: ...adrant is at the most right side rotate the adjusting screw that can be seen through C hole of Fig 2 e g In Image 4 the arrow point of the 1st quadrant is at the most right side so rotate the adjusting screw that can be seen through A hole of Fig 2 Image 4 Fig 2 1st quadrant 2nd quadrant 3rd quadrant 4th quadrant Viewed from lens backward A B C Index position After the adjustment apply the screw l...

Page 93: ...htly smaller than the actual size of viewers makes it easier to fit the positions of viewers tightly 3 2 Put the 2nd flattened cardboard box size 2 33 and the above cut out 1st cardboard together as one and fix them by taping at 4 sides ref Fig 3 on next page 3 3 Then as for the 2nd flattened cardboard box cut out the shape again by matching the cut out size of 3 1 for each viewer ref Fig 4 on nex...

Page 94: ...t the 2nd flattened cardboard box and the1st cut out cardboard together as one as shown below Fig 4 Regarding the 2nd flattened cardboard box cut out in the same way as Fig 2 All cardboards are as below Cut on the same shape outlined in red as in the 1st cardboard Fig 5 Light viewers are embedded Fix them by taping at 4 sides To prevent viewers falling off secure the viewers with tape around the s...

Page 95: ...INC JAA79551 R 3690 A A 68 AF S VR 70 300 4 5 5 6G Rear cover ring 92 3 Zoom rubber Rear cover ring Zoom rubber ...

Page 96: ... glass lens chamber is replaced or when each lens part is disassembled Be sure to make this adjustment after completing inspecting and adjusting the main PCB 1 Preparation Test chart Self made tool ref Procedure for how to create it Tripod D100 Personal computer USB cable UC E4 Adjustment software LWM exe used for the lens optical alignment 2 Procedure for how to create Test chart Photocopy the ne...

Page 97: ...INC JAA79551 R 3690 A A 70 AF S VR 70 300 4 5 5 6G Target chart Resolution chart ...

Page 98: ...L WB to Preset and ISO to 200 Set up the camera D100 in which the lens to be inspected is fit on the tripod Set the focal length to 300 mm and the distance between the test chart and camera CCD face to 9 m 00 2 cm 9 m 00 2 cm Test chart As shown below set the center of the focus area on the chart within viewfinder Target chart Within viewfinder Resolution chart Connect the PC and camera via USB ca...

Page 99: ...INC JAA79551 R 3690 A A 72 AF S VR 70 300 4 5 5 6G Confirm that AF S VR 70 300 4 5 5 6G is selected on Lens select screen Click OK Click the Defocus rectify button ...

Page 100: ...check which chart is in focus of the 5 resolution charts Caution Because this lens has a deep focal depth even if the aperture is fully open when looking for the center of focus compare two distant charts between which there are two or more charts 100μ m 100μ m 50μ m 50μ m 0μ m Input the value of the focused position into the entry field e g The below is the case when 100μm of the front focus side...

Page 101: ...a CCD face to 2 m 80 2 cm Caution Confirm that the aperture is full open Perform the operations from to of the previous page Check that the values of all the focal lengths are displayed within the dotted red circle Then click on Rewriting When A compensation value is written in is displayed click OK Revision 10 December 15 2006 Changed page 1 ...

Page 102: ... is turned off once the value that was written in EEPROM is not reflected When the adjustment software restarts perform the operations from to again Check that 0μm of the AF position is in focus It is also possible after Wide side shooting of to take the Tele side shooting of If 0μm is not in focus repeat the operations from to If it is not still in focus even after repetition the written value in...

Page 103: ...GMR magnetic tape FPC with GMR sensor To SWM unit SWM FPC Focus mode Main unit VCM connecting FPC power source PSD connecting FPC terminal Unit PCB Unit LED FPC Rotation detector for Manual focus ring Zoom encoder Lock VCM Gyro FPC unit ー E1 AF S VR 70 300 4 5 5 6G ー VR mode VR ON OFF Main unit CN side IC 面 IC side ...

Page 104: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G 外観図 Sketch drawings ...

Page 105: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G 組立図 Structure of the Lens ...

Page 106: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...

Page 107: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...

Page 108: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...

Page 109: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...

Page 110: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...

Page 111: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...

Page 112: ...点検 調整ソフト ADJ FD FOR AF S VR70 300 IBM 3 5 J18004 1 J18004用基準ゲージ STANDARD GAUGE FOR J18004 J15306 1 AF I通信ボックス AF I LENS COMMUNICATION BOX CE J15307 AF I通信アダプター COMMUNICATION ADAPTER FOR AF I 自作工具 RJNo is not available 自作工具 SELF MADE TOOL FOR AF S VR18 200 J11337 G2 G3 部組 組込み工具 AF SVR70 300 G2 G3UNIT ASSEMBLING TOOL J11338 レンズ受け台 AF SVR70 300 LENS STAND J11339 無限ピン AF SVR70 300 INFINITY PIN J15380 ...

Page 113: ...DER RMA02 M705 0 5MMX500G 工具設定なし RJNo is not available へクスキー φ 1 27mm HEX KEY WRENCH φ 1 27mm J19128 調芯装置用チャート LENS ALIGNMENT CHART J19128A ライトビューワー J19128 用 LIGHT VIEWER J19128 J19129 調芯装置用スライドレール LENZ ALIGNMENT EQUIP SLIDE RAIL 工具設定なし RJNo is not available オシロスコープ OSCILLOSCOP I 40 AFレンズ用グリ ス I 40 GREASE FOR AF LENS EDB0011 ネシ ロック 赤 1401C SCREW LOCK 1401C C 8008B セメダイン 黒 CEMEDAIN 8008 BLACK MZ 80...

Page 114: ...S グリ ス GP 1RS GREASE GP 1RS FOR AF S 18 135 L 241 ロックタイト 241 青 LOCTITE 241 50ml OS 30MF ドライサ フ OS 30MF DRY SERF OS 30MF OIL BARRIER F 890 ドライルーブ F 890 1L DRILUBE F 890 1L GN 20S グリ ス GN 20S SQ 用 GREASE GN 20S SQ NKS 211SP 接点潤滑剤 NKS 211SP POINT OF CONTACT LUBRICANT NKS 211SP FOR AF S 18 135 ...

Page 115: ... DX 18 200 4 5 5 6G of RP If there is a defective main PCB after replacements repairs use the defective one Make a self made tool according to the following procedure Making of Self made Tool Main PCB Use this range Connector Remove the mounted parts elements condenser transistor IC etc from the both faces of the PCB within the range of the dotted lines See the left Do not remove the connector The...