HMI Bypass Controller Installation and Commissioning Guide
2.3 Part Number Identification
www.hvacr-drives.com
Page 21
Order from Eden Prairie, MN:
P: 952-995-8111, F: 952-995-8129
PLH 2018 v1.0
Order Code Configurator
HVAC/R Packaged Drives
BASE ORDER CODE
POWER & DOOR OPERATOR OPTIONS
CONTROL OPTIONS
P X X X X X N X X X
-
X
0
X
X
X
X
X
0
-
X X X X 0 X X X X X
1 2
3 - 6
7 8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
[Order Code
digit number]
Packaged HVAC/R Drives from 1 to 600 hp
[27] Basin Heater**
0 = None
1 = 1 kW
2 = 2 kW
3 = 3 kW
4 = 4 kW
5 = 5 kW
6 = 6 kW
7 = 7 kW
8 = 8 kW
9 = 9 kW
A = 10 kW
B = 11 kW
C = 12 kW
D = 13 kW
E = 14 kW
F = 15 kW
G = 16 kW
H = 17 kW
I = 18 kW
J = 19 kW
K = 20 kW
[28] Spray Pump***
0 = None
1 = 1 HP
2 = 2 HP
3 = 3 HP
5 = 5 HP
7 = 7 HP
A = 10 HP
B = 15 HP
[29] De-icer / Sun Shield***
0 = None
1 = De-icer
2 = Sun Shield
3 = De-icer & Sun Shield
[30] Siemens FLN
0 = None
1 = Yes
[12] Bypass Options
0 = No Bypass
1 = Electronic 3-Contactor Bypass
2 = Manual Bypass
3 = HMI 2-Contactor Bypass
with VFD Service Swtich
4 = HMI 2-Contactor Bypass
6 = Soft Starter 3-Contactor Bypass
[14] Door-Mounted Keypad/HMI
0 = None
C = LCD Keypad
E = LED Keypad
H = Door-mounted Touchscreen HMI
E = LED Keypad
Unidrive M200 includes LED keypad as standard.
Affinity BA includes LCD keypad as standard.
[15] Input Filtering
0 = None
1 = Input Reactor 3%
2 = Input Reactor 5%
3 = RFI Filter
4 = Input Reactor 3% + RFI Filter
5 = Input Reactor 5% + RFI Filter
6 = Matrix AP Filter
Enclosure size considerations. Addition of one or
multiple filtering options may change the size
and/or style of the enclosure.
Matrix filter - consult factory.
[16] Output Filtering
0 = None
1 = Output Reactor 3%
2 = dV/dt Filter
3 = Sine Filter
4 = Output Reactor 1.5%
[17] Multiple Motors
0 = None Drive Protected
2 = Two Manual Motor Protectors (MMP)
3 = Three Manual Motor Protectors
4 = Four Manual Motor Protectors
5 = Five Manual Motor Protectors
6 = Six Manual Motor Protectors
Cumulative amp ratings of motors must not
exceed the drive rating. Each motor must have its
own overload protection. Multiple Manual Motor
Protectors are of equal size.
[18] Space Heater**
0 = None
2 = 200 W
4 = 400 W
Larger heaters can be chosen for extremely cold
ambient temperatures.
[21] - [23] Option Modules
0 = None
A = SM-APPS-LITE-V2
C = SM-BIPOLAR
D = SM-CANOPEN
E = SM-DEVICENET
H = SM-ETHERCAT
I = SM-ETHERNET
K = SM-I/O-120V
L = SM-I/O-24V
M = SM-I/O-32
N = SM-I/O-LITE
P = SM-I/O-PLUS
Q = SM-I/O-TIMER
R = SM-INTERBUS
S = SM-LON
T = SM-PROFIBUS-DP
V = SM-REGISTER
W = SI-I/O*
Y = AI-485-ADAPTOR*
Z = KI-485-ADAPTOR*
1 = SI-PROFIBUS*
2 = SI-ETHERNET*
3 = SI-DEVICENET*
4 = SI-CANOPEN*
5 = SI-PROFINET-V2*
6 = SI-ETHERCAT*
Unidrive M200 has 1 option
module slot only, Affinity has 2
option module slots, HVAC Drive
H300 has 3 option slots
[24] Phase Loss Monitor
0 = None
1 = Yes
[26] Temperature Controller***
0 = None
1 = Thermocouple
2 = RTD
[1] Package Types
G = Pre-Engineered, New Generation
P = Pre-Engineered
S = Seismic*
C = Custom*
*Contact Factory
[2] Voltage Ratings
8 = 208 Vac
2 = 230 Vac
4 = 460 Vac
5 = 575 Vac
[3] - [6] Horsepower Ratings
0001 = 1 HP
0060 = 60 HP
01P5 = 1.5 HP
0075 = 75 HP
0002 = 2 HP
0100 = 100 HP
0003 = 3 HP
0125 = 125 HP
0005 = 5 HP
0150 = 150 HP
0007 = 7.5 HP
0200 = 200 HP
0010 = 10 HP
0250 = 250 HP
0015 = 15 HP
0300 = 300 HP
0020 = 20 HP
0350 = 350 HP
0025 = 25 HP
0400 = 400 HP
0030 = 30 HP
0450 = 450 HP
0040 = 40 HP
0500 = 500 HP
0050 = 50 HP
0600 = 600 HP
[7] Duty Ratings
N = Normal Duty
[8] Enclosure Styles
1 = NEMA 1
2 = NEMA 12
3 = NEMA 3R
4 = NEMA 4X
B = NEMA 1 (Bypass Only)
F = NEMA 1 (Disconnect with Fusing)
[9] Input Power Connections
1 = Circuit Breaker (25 kAIC)
2 = Disconnect Switch with Fusing
3 = Circuit Breaker (65 kAIC)
4 = Circuit Breaker (100 kAIC)
5 = Fused Disconnect (100 kAIC)
Input fuses for drives are included as
standard for all input power options
[10] Products
A = Affinity Active Front End
B = Affinity Drive
2 = Unidrive M200
3 = HVAC Drive H300
X = HVAC Drive H300 AFE
*SI options used with Unidrive M200 & HVAC Drive H300
**Available with NEMA 3R enclosure only
***Selection of options 26-29 require a cooling tower NEMA 3R enclosure.
NOTE:
For options not included in the Order Code Configurator, please consult
factory for a custom quote.
Summary of Contents for Control Techniques HVAC Drive H300 HMI Bypass
Page 17: ...HMI Bypass Controller Installation and Commissioning Guide 17...
Page 53: ...HMI Bypass Controller Installation and Commissioning Guide 53 Notes...
Page 54: ...54 HMI Bypass Controller Installation and Commissioning Guide Notes...
Page 55: ...HMI Bypass Controller Installation and Commissioning Guide 55 Notes...