HEHR DOUBLE-LATCHED EMERGENCY EXIT WINDOW
TO OPEN THE EMERGENCY EXIT DOUBLE LATCH
STYLE WINDOW:
1. Flip both latches up to the open position.
2. Push out on the window.
TO CLOSE AND LATCH THE EMERGENCY EXIT
DOUBLE LATCH STYLE WINDOW:
1. Pull the window shut while holding the window
track with one hand.
2. With the other hand, rotate the latch up until it
connects with the track on the window.
3. Press the front side down until it latches.
4. Repeat the steps for the second latch.
HOW TO CLEAN THE WINDOWS
Most windows used by Newmar are equipped with sliding screens that can be removed for cleaning.
1
REMOVING THE SCREEN
Open the window and screen. Press upward on the screen frame top, pushing the frame deeper into its pocket. This will
compress the springs and allow the screen frame bottom to rotate out of the bottom track. Be careful with the plastic
screen springs, so that they can be re-used.
CLEANING THE GLASS
Apply straight mineral spirits to a clean, soft cloth and wipe the glass. Dry with a clean cloth Next, clean the glass again,
using a clean cloth with a 50-50 mix of water and a household window cleaner like Windex
™
or GlassPlus
™
. If there is
still a residue, remove it with rubbing alcohol and dry.
HOW TO PREVENT WINDOW CONDENSATION
IMPORTANT
Since surface condensation within the coach cannot be controlled by the manufacturer, damage caused by
condensation is not covered by your Newmar Limited Warranty.
Damage may occur to your unit if excessive condensation exists. Accumulation of condensation on surfaces within your
unit occurs when warm, moist air contacts a cool surface. It is most evident on the inside of windows. This problem can
be controlled by:
1. Slightly opening a window or roof vent to allow the moisture to escape from the unit.
2. A small dehumidifier is also very effective in removing moisture from the air.
Condensation levels are highest during times when a person is cooking or taking a shower in the unit, but these are not
the only times condensation is present. Condensation can migrate through ceiling panels and saturate the fiberglass
insulation in your ceiling cavity. This condition often causes the occupants to believe the recreational vehicle has a roof
leak. Walls and ceiling panels may also become wet when the moisture accumulates on these surfaces.
IMPORTANT
Newmar Corporation does not recommend the use of any catalytic heaters.
FOR MORE INFORMATION
Refer to the product manufacturer's owner's manual and links in Newgle to learn more about your coach's windows.
© 2018 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
91