IMPORTANT
Newmar recommends the value for "search watts" be
set to '25 Watts.'
INVERTER STATUS
This shows the current status of the inverter, which can be
displayed as one of the following:
• Off: Inverter is turned off
• On: Inverter is turned on and will invert with no
supplied AC power or go into standby mode if AC
power is being provided to the inverter
• Standby: Inverter is turned on, but AC power is
supplied to the inverter via shore power or generator
CHARGER STATUS
This shows the current charger status, which can be
displayed as one of the following:
• Standby: No AC current is present
• Bulk: First stage of charging (aggressive charge)
• Absorb: Charging at a value the batteries will accept
• Float: Reduced charge to finish or top off a battery
AC BREAKER SIZE
This displays the capacity of the physical breaker inline with the inverter in the electrical panel. This breaker size can be
changed in increments of five (5) amps.
IMPORTANT
Newmar recommends the value for "AC Breaker Size" be set to '30 Amps.'
SEARCH MODE
When set to 'disable,' the inverter is turned on. Set to 'enable' to allow the search watts and search delay functions of the
next screen.
SEARCH WATTS
This is the amount of wattage consumption needed to start
the inverter. This value is changed by using the arrows to
increase or decrease the wattage setting. The Search Watts
can be changed in increments of five (5) watts.
SEARCH DELAY
This is the amount of time [in seconds] for search watts to be completed before the inverter will start. This value is
changed by using the arrows to increase or decrease the amount of time.
IMPORTANT
Newmar recommends the value for "search delay" be set to '2 seconds.'