ELECTRICAL
BEFORE STARTING THE GENERATOR:
1. Turn o
ff
the air conditioners and any other large
electrical loads, as recommended by the generator
manufacturer.
2. If the generator previously ran out of fuel, add fuel to
the tank.
3. Prime the generator by holding the generator switch
in the stop position.
TO START THE GENERATOR:
1. Press and hold the generator start switch in the “Start/
Preheat” position. It will automatically delay and pre-
heat.
2. The indicator light will flash rapidly while pre-heating,
and the generator will crank and start.
3. When the generator starts, release the switch.
4. The indicator light will stay illuminated while the
generator is running.
TO STOP THE GENERATOR:
1. Press the generator switch in the “Stop” position.
2. Release the switch.
3. The indicator light will turn o
ff
when the generator
stops.
Service Required Indicator:
1. The generator switch indicator light may flash in a
series of three quick flashes, followed by a short
pause, and then quickly flash three more times. These
flashes indicate that service is required.
2. Refer to the owner’s manual for your specific
generator for more in-depth descriptions of flashing
codes.
CAUTION
!
Failure to turn o
ff
the 120 volt appliances when
starting or stopping the generator may damage the
transfer switch and/or electrical appliances.
Excessive cranking can damage the starter motor.
Do not crank the generator more than 30 seconds at
a time, and allow at least two minutes before trying
again if the first attempt fails.
IMPORTANT
!
If your coach contains an Energy Management System,
8kw generator, and three roof air conditioners, the
combined load may exceed the capabilities of the
generator. Please remember to turn o
ff
one of the air
conditioners as the 8kw generator is not intended to
run all three roof air conditioners at the same time.
NOTICE
!
To Operate The HWH Hydraulic Generator Slide:
1. Turn on the ignition key.
2. Open the compartment located in front of the first wheel on the driver’s side.
3. Locate the generator slide switch.
4. Press and hold the switch in the “extend” position until the generator slide reaches the
desired position or maximum extension.
To Close The Generator Slide:
1. Turn on the ignition key.
2. Open the compartment located in front of the first wheel on the driver’s side.
3. Locate the generator slide switch.
4. Press and hold the switch in the “retract” position until the generator slide is fully retracted.
How To Operate The Hydraulic Generator Slide