© 2020 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
143
HVAC
Domestic Hot Water via Oasis Hydronic Heating
This article provides a basic overview of domestic hot water via the Oasis hydronic heating system.
CH50
NE-S
CHINOOK
BTU
50,000
85,000
50,000
Maximum Water Temperature
(at incoming water temperature of 60°F)
120°F
120°F
120°F
Gallons Per Minute (GPM)
1.5
3.0
1.5
Potable Hot Water Capacity
The hot water in your coach is heated by the Oasis
hydronic heating system. To operate an appliance that
uses hot water, or to assure plenty of hot water for
showering, turn on the boiler or heating elements using
the Oasis control panel or the SilverLeaf touchscreen (if
equipped) located in the front overhead cabinet.
Both heat sources (boiler and heating elements) can be
used at the same time for the desired maximum water
heating capability. Turning the 120 volt heating element
on will usually provide su
ffi
cient hot water for most
household chores.
Oasis Service Scheduling
This article provides information on Oasis Service intervals, including parts and time needed to complete each job.
1 YEAR SERVICE (1 hour)
Newmar Part #
Name of Part
Vendor # (Oasis)
013607
Igniter
9002
013790
Garber Fuel Filter
6022
019711
Air Filter
6018AF
013847
Nozzle Filter
14023
016307A
Nozzle O-Ring
14025
3 YEAR SERVICE (1.5 hours)
Newmar Part #
Name of Part
Vendor # (Oasis)
013607
Igniter
9002
013790
Garber Fuel Filter
6022
019711
Air Filter
6018AF
013847
Nozzle Filter
14023
016307A
Nozzle O-Ring
14025
016301
Secondary Filter
6027
016147
Digital Flame Sensor
20106
5 YEAR SERVICE (2 hour)
Newmar Part #
Name of Part
Vendor # (Oasis)
016307
Nozzle
14070
013607
Igniter
9002
013790
Garber Fuel Filter
6022
019711
Air Filter
6018AF
013847
Nozzle Filter
14023
016307A
Nozzle O-Ring
14025
016301
Secondary Filter
6027
013848
Fuel Pump
16015