PLUMBING
Oasis Hydronic Heating Basement Heat Convector(s)
Coaches with Oasis Hydronic Heating will have a heat exchanger, dual fans, and a designated thermostat. The basement
heat is activated by a separate fixed thermostat in the basement area when the compartment temperature falls below
approximately 40 degrees Fahrenheit. If this happens, the hot antifreeze solution in the Oasis system will circulate, and the
blower will turn on to supply heat in the basement/water compartment area. The Oasis system must be turned on and the
fluid must be above the low temperature cutout for heat output.
Water Compartment Heating: Oasis Operation via
SilverLeaf
Oasis Basement Heat Exchanger
Oasis Dual Fan on Basement Heat Exchanger
Oasis Bi-Metallic Thermostat
Oasis Operation via SilverLeaf
The Oasis System must be turned on from the SilverLeaf
touchscreen, and the water temperature in the Oasis
System must be up to temperature for the basement heat
to work. The basement heat only works when the furnace
(Oasis System) is activated. It will NOT function if the
Oasis System is o
ff
and the coach is being heated via the
roof air conditioner heat pumps.
The Fresh Water System consists of the fresh water holding tank, water pump, valves, connection hoses,
and fresh water plumbing lines. This system is responsible for providing potable water for drinking, cooking,
bathing, and all other activities that require clean water. The capacity of your fresh water tank may vary,
depending on the coach model and year.
Fresh Water System
Fresh Water Lines, Low Point Drains, and Plumbing Leaks
This article provides a basic overview of Fresh Water Lines, Low Point Drains, and Plumbing Leaks.
Fresh water lines are used to distribute potable water
throughout the coach. The hot water lines are typically
red in color or translucent with red lettering. The cold
water lines are typically blue in color or translucent with
blue or black lettering. Fresh water lines located beneath
the slideout floor are typically heated to prevent freezing
(i.e. refrigerator water supply). The water lines are routed
in the heated water bay and inside the heated living area
as much as possible.