© 2021 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
36
APPLIANCES
Norcold Refrigerator Operation (Model: N10 Series)
This article provides basic operation instructions for a Norcold Refrigerator with Ice Maker (Model: N10 Series).
Operating The Controls
IGNITION AND START UP
•
Make sure the air flow in the lower intake vent,
through the refrigerator coils and condenser, and out
the upper exhaust vent is not blocked or decreased.
•
Make sure there are no combustible materials in or
around the refrigerator.
•
Make sure the DC voltage to the refrigerator is
12.0VDC
AIR IN THE PROPANE GAS SUPPLY
LINES
Notice: For safety reasons,the refrigerators electronic
controls are designed such that while operating in the
LP GAS mode, the trial for ignition (maximum amount of
the time the gas valve and igniter can be left on without
a flame present) is limited to 30 seconds. When starting
the refrigerator for the first time, after storage, or after
replacing the propane gas tank, the propane gas supply
lines can have air in them.
Due to air in the gas supply lines, the burner may not
ignite within the 30 second time limit. In the event this
should happen the gas valve and igniter outputs will be
turned off, the LP Gas mode will be “locked out”, and the
appropriate fault code will be shown in the display.
The gas lock out condition can be reset by powering
the refrigerator OFF and then back ON, at which time, a
new 30 second trial for ignition will commence. It may be
necessary to repeat this procedure several times before
expelling all the air from the LP gas supply line. If after
repeated attempts, a flame is not established, stop and
consult your local dealer or Authorized Norcold Service
Center.
AUTOMATIC MODE OPERATION:
•
Touch and release the ON/OFF button [30] to turn the
refrigerator on.
•
Touch the TEMP SET button [32] as needed to set the
temperature setting.
❒
Number one (1) shown in the display [187] is the
warmest setting.
❒
Number nine (9) shown in the display [187] is the
coldest setting.
IF NEITHER 120 VOLTS AC NOR
PROPANE GAS ARE AVAILABLE TO THE
REFRIGERATOR :
•
2-way refrigerators:
❒
The fault codes “no AC” and then “no FL” show in
the display and an audible alarm sounds.
❒
Refer to the “Fault Codes” section of the
refrigerator’s manual for any faults displayed.
•
3-way refrigerators only:
❒
The Auto icon and the Battery icon [361] are lit up.
❒
After ten seconds, the backlight of the display goes
off.
❒
This means that the refrigerator is operating on DC
electric.
IF AN ENERGY SOURCE IS AVAILABLE
TO THE REFRIGERATOR BUT IS NOT
OPERATING CORRECTLY:
•
While operating in the Automatic mode, the
refrigerators electronic controls will automatically
select the energy source using the following priority
scheme:
❒
1st choice: AC Electric
❒
2nd choice: LP GAS
▷
When in the Auto mode, if a higher priority
choice becomes available (i.e., AC voltage
reapplied), the control shall stop using the
current mode and switch to the higher priority
mode.
•
If the AUTO icon [277] and AC PLUG icon [278] are lit
up, it means that:
❒
120 volt AC power is available to the refrigerator.
❒
The refrigerator is operating on AC electric power.
❒
After ten seconds, the backlight of the display goes
off.
•
If the AUTO icon and the FLAME icon [289] are lit up,
it means that:
❒
120 volt AC power is not available to the
refrigerator.
❒
The refrigerator is operating on propane gas.
❒
After ten seconds, the backlight of the display goes
off.
Summary of Contents for Bay Star 2022
Page 1: ...SM 2022...