Connecting Power to the UPS
This section contains the instructions for connecting the UPS to
the Gateway. The UPS requires 120 VAC on the input and
provides 12 VDC output to the Gateway.
Connect the UPS according to the manufacturer's
instructions. Install the UPS only in a well-ventilated
area that is free from explosive or corrosive gases,
vapor, or excessive dust, dirt, and moisture. Ensure a
free flow of air around the UPS.
Wiring the AC-Power for the UPS and Gateway must be
done by a licensed electrician. Install in accordance with
the National Electrical Code, Canadian Electrical Code,
and local electrical codes
.
The integrity of the protective earthing should be
ensured when installed.
The AC input to the UPS must have a readily accessible
disconnect device installed.
Figure 69 – Inside of the UPS
1. Remove the two cover screws from the UPS cover, and
then remove the cover. See Figure 69.
2. Wire the 120 VAC input through the lower 1/2 inch
(12 mm) diameter knockout hole.
3. Wire the 12 VDC output through the upper 1/2 inch
(12 mm) diameter knockout hole. See Figure 69.
4. Attach the circular power connector (12 VDC) to the
Gateway by pushing and rotating the connector
clockwise to engage it.
5. Turn on the power switch inside the UPS to activate the
system. See Figure 77 – page 58. Also see "Checking
6. Install the cover on the UPS and secure it with the two
cover screws.
54
R900 Gateway Installation and Maintenance Guide
Chapter 4: Installation of the Gateway