![Neptune 13458-000 Installation And Maintenance Manual Download Page 110](http://html1.mh-extra.com/html/neptune/13458-000/13458-000_installation-and-maintenance-manual_1668232110.webp)
Display
Error Condition
E01
Rotary switch battery selection failure
E03
Voltage reference test failed (circuit, malfunctions)
E04
Solar array current fault (circuit, (FET
1
)
E07
Load FETs off test (load connection, FETs shorted)
E08
Load current fault (circuit, FETs)
E09
Load FETs on test (load circuit, FETs open)
E10
Internal temp sensor out of range high
E11
Internal temp sensor out of range low
E12
Remote temp probe out of range
E13
Battery sense fault (battery V drop over 5V, no Sense
negative connection)
1
Field-Effect Transistor
Table 23 – Fault Error List
Terminate the Self Test
To terminate the self test, push the button. The self-test can be
repeated to confirm the result.
Select Battery Type
The ProStar controllers contain a battery type rotary switch that
allows the selection of one of three charging algothrithms. Set the
Battery Type switch to
position 2
(Sealed: AGM). The switch
positions are defined as the following battery types shown in
Table 24.
Switch Position
Battery Type
1
Gel
: Some gel and other battery types recommend lower
regulation voltages and no equalization. This setting
regulates to 14.0V (for a 12V battery).
2
Sealed
: AGM, "maintenance free" and some types of gel
batteries. Regulates to 14.15V (12V battery) with 14.35V
boost charging.
3
Flooded
: Vented cells that require water to be added.
Regulates to 14.4V with 14.9V and 15.1V equalizations
(12V battery).
Table 24 – Battery Type Switch Positions