Replacing a Battery Backup Unit
If the battery backup unit is defected, the Service LED on the disk array unit lights
orange. In addition, the Fault LED on the power supply corresponding to the defected
battery backup unit, PS0 for BBU0 or PS1 for BBU1, lights orange. The defected
battery backup unit may be replaced with a new one without powering off the disk array
unit.
The Power Fault LED lights orange when the power supply is defected,
even if the battery backup unit on the power supply works normally. Use
NEC Storage Manager to identify the defected unit.
When replacing a battery backup unit, prepare the new battery backup
unit before removing the old one, and then replace it within about 5
minutes. If the power supply is removed for longer than 5 minutes, the
shutdown sequence is executed by the security feature of the disk array
unit.
Read the entire procedure before replacing the battery backup unit.
Follow the procedure below to replace a battery backup unit.
1.
Remove the power supply on which the defective battery backup unit is installed,
and then remove the battery backup unit (see previous section
Replacing a Power
Supply Unit
).
2.
Install the new battery backup unit to the power supply, and then install the power
supply in the disk array unit (see previous section
Replacing a Power Supply Unit
).
4-16 Problem
Solving
Summary of Contents for VERSA S1300 Series
Page 1: ... U s e r s G u i d e NEC Storage S1300 ...
Page 2: ......
Page 4: ......
Page 8: ...vi Contents ...
Page 18: ...xvi Using This Guide ...
Page 19: ...1 System Overview Overview System Chassis System Features ...
Page 54: ...A B Figure 2 3 Installing the Rack Mounting Kit 2 6 Setting Up the System ...
Page 73: ...3 Upgrading the System Overview Adding Hard Disk Drives Adding Disk Enclosures ...
Page 86: ...3 14 Upgrading the System ...
Page 114: ...A 8 Appendix ...
Page 117: ...xx ...
Page 118: ... ...