4-44 Configuring Your Server
7.
Press
F10
to create virtual drive.
The "Virtual Drives Configured" screen appears. (The figure below shows an example of
RAID1 configured with two hard disk drives.)
8.
Select "RAID," "Size", "DWC", "RA", or "Span" by using cursor keys. Then press
Enter
to fix the selection and set each value.
(1) "RAID": Sets RAID level.
Parameter
Remarks
0
RAID0
1
RAID1
10
Striping of RAID1
The selectable RAID level varies depending on the number of hard disk drives
that configure a pack.
(2) "Size": Sets virtual drive size.
Up to 8 virtual drives can be created per RAID Controller.
(3) "DWC": Sets parameter for Disk Write Cache.
Parameter
Remarks
Off
Write through
On *
1
Write back
*1 Recommended setting.
"Write-back On" enables good performance, however, cache data may be lost at
an unexpected power failure. "Write-back Off" reduces performance by
approximately 50%.
(4) "RA": Sets parameter for Read Ahead.
Parameter
Remarks
Off
Does not perform read ahead.
On
Performs read ahead.
Summary of Contents for N8100-1447F
Page 31: ...General Description 2 5 Rear View 1 2 3 2 4 5 6 7 8 9 10 12 11 13...
Page 48: ...2 22 General Description This page is intentionally left blank...
Page 216: ...9 6 Upgrading Your Server 3 Loosen the two screws 4 Hold the side cover securely to remove it...
Page 217: ...Upgrading Your Server 9 7 5 Position the server until on its right side...
Page 256: ...9 46 Upgrading Your Server This page is intentionally left blank...
Page 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank...
Page 268: ...A 2 Specifications This page is intentionally left blank...
Page 276: ...C 2 IRQ This page is intentionally left blank...
Page 328: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 332: ...G 4 Product Configuration Record Table This page is intentionally left blank...