CHAPTER 11 STANDBY FUNCTION
User's Manual U11919EJ3V0UM00
172
11.2.2 STOP mode
(1)
Setting and operation status of STOP mode
The STOP mode is set by executing the STOP instruction.
Caution
Because the standby mode can be released by an interrupt request signal, the standby mode is
released as soon as it is set if there is an interrupt source whose interrupt request flag is set
and interrupt mask flag is reset. When the STOP mode is set, therefore, the HALT mode is set
immediately after the STOP instruction has been executed, the wait time set by the oscillation
settling time select register (OSTS) elapses, and then operation mode is set.
The operation status in the STOP mode is shown in the following table.
Table 11-3. STOP Mode Operating Status
Item
STOP Mode Operation Status
Clock generation circuit
Stops system clock oscillation
CPU
Stops operation
Port (Output latch)
Retains the status before setting the STOP mode
16-bit timer
Stops operation
8-bit timer/event counter
Operation is enabled only when TI0 is selected as the count clock
Watchdog timer
Stops operation
Serial interface
Enables operation only when input clock from external is selected as serial clock
External interrupt
Operation enabled
Key return
Only the pin set to key return mode is enabled
Summary of Contents for mPD789026 Subseries
Page 2: ...User s Manual U11919EJ3V0UM00 2 MEMO...
Page 8: ...User s Manual U11919EJ3V0UM00 8 MEMO...
Page 12: ...User s Manual U11919EJ3V0UM00 12 MEMO...
Page 22: ...User s Manual U11919EJ3V0UM00 22 MEMO...
Page 32: ...User s Manual U11919EJ3V0UM00 32 MEMO...
Page 84: ...User s Manual U11919EJ3V0UM00 84 MEMO...
Page 92: ...User s Manual U11919EJ3V0UM00 92 MEMO...
Page 104: ...User s Manual U11919EJ3V0UM00 104 MEMO...
Page 166: ...User s Manual U11919EJ3V0UM00 166 MEMO...
Page 178: ...User s Manual U11919EJ3V0UM00 178 MEMO...
Page 184: ...User s Manual U11919EJ3V0UM00 184 MEMO...
Page 204: ...User s Manual U11919EJ3V0UM00 204 MEMO...
Page 206: ...User s Manual U11919EJ3V0UM00 206 MEMO...