CHAPTER 9 SERIAL INTERFACE 00
User's Manual U11919EJ3V0UM00
141
(c) Transmission
A transmit operation is started by writing transmit data to transmit shift register 00 (TXS00). The start
bit, parity bit, and stop bit(s) are added automatically.
When the transmit operation starts, the data in TXS00 is shifted out, and when TXS00 is empty, a
transmission completion interrupt (INTST) is generated.
Figure 9-8. Asynchronous Serial Interface Transmission Completion Interrupt Timing
(a) Stop bit length: 1
STOP
Parity
D7
D6
D2
D1
D0
START
TxD (Output)
INTST
(b) Stop bit length: 2
STOP
Parity
D7
D6
D2
D1
D0
START
TxD (Output)
INTST
Caution
Do not rewrite to asynchronous serial interface mode register 00 (ASIM00) during a
transmit operation. If the ASIM00 register is rewritten to during transmission,
subsequent transmission may not be performed (the normal state is restored by
RESET input).
It is possible to determine whether transmission is in progress by software by using a
transmission completion interrupt (INTST) or the interrupt request flag (STIF00) set by
INTST.
Summary of Contents for mPD789026 Subseries
Page 2: ...User s Manual U11919EJ3V0UM00 2 MEMO...
Page 8: ...User s Manual U11919EJ3V0UM00 8 MEMO...
Page 12: ...User s Manual U11919EJ3V0UM00 12 MEMO...
Page 22: ...User s Manual U11919EJ3V0UM00 22 MEMO...
Page 32: ...User s Manual U11919EJ3V0UM00 32 MEMO...
Page 84: ...User s Manual U11919EJ3V0UM00 84 MEMO...
Page 92: ...User s Manual U11919EJ3V0UM00 92 MEMO...
Page 104: ...User s Manual U11919EJ3V0UM00 104 MEMO...
Page 166: ...User s Manual U11919EJ3V0UM00 166 MEMO...
Page 178: ...User s Manual U11919EJ3V0UM00 178 MEMO...
Page 184: ...User s Manual U11919EJ3V0UM00 184 MEMO...
Page 204: ...User s Manual U11919EJ3V0UM00 204 MEMO...
Page 206: ...User s Manual U11919EJ3V0UM00 206 MEMO...