1. Installing Internal Optional Devices
Express5800/T120h User’s Guide
67
Chapter 2 Preparations
Identifying processor type
The type of processor installed on the server is displayed simply on the POST.
If you need to confirm detailed information on processor type or specification of additional processor, follow the
procedure below.
1.
Reboot the server.
The server restarts and the POST screen is displayed.
2.
Press <F9>
System Utility screen appears.
3.
Select
System Information > Processor Information
.
More information about the processors installed on the server appears on the screen.
4.
Keep pressing <
ESC
> until the main menu is displayed.
5.
After the menu below is displayed, select [OK] to leave System Utility and move to Boot mode.
Replacement / Removal
Important Do not remove any CPU unless it is failed.
To remove the heat sink from the CPU, first turn the heat sink to the left and
right lightly to make sure that the heat sink can be apart from the CPU.
Removing the heat sink with it adhering to the CPU may cause the CPU
and/or CPU socket to be defected.
In case you take off the CPU but do not fit a protection cover or dummy
cover, the cooling effect declines and the device may break down.
To remove CPU, reverse the installation procedure.
Also follow the steps below if the CPU was removed.
1.
Mount the protective cover to CPU socket.
2.
Remove the redundant fan kit.
3.
Attach the fan blank cover.