1. Error Message of POST and Virtual LCD
Express5800/B120g-h Maintenance Guide
153
Chapter 3 Appendix
Error Message
Cause
Solution
B341 Mezzanine Slot 1 - PCIE Link
Failure
Connection failure of PCIe bus was
detected on Mezzanine Slot 1.
Contact your sales representative.
B342 Mezzanine Slot 2 - PCIE Link
Failure
Connection failure of PCIe bus was
detected on Mezzanine Slot 2.
B343 Mezzanine Slot 3 - PCIE Link
Failure
Connection failure of PCIe bus was
detected on Mezzanine Slot 3.
B344 Mezzanine Slot 4 - PCIE Link
Failure
Connection failure of PCIe bus was
detected on Mezzanine Slot 4.
B348 PCI Slot - PCIE Link Failure
Link Width error was detected on
PCI Slot.
B34A I/O Blade PCI Slot - PCIE Link
Failure
Connection failure of PCIe bus was
detected on I/O Blade PCI Slot.
B371 Mezzanine Slot 1 - PCIE Link
Width Error
Link Width error was detected on
Mezzanine Slot 1.
B372 Mezzanine Slot 2 - PCIE Link
Width Error
Link Width error was detected on
Mezzanine Slot 2.
B373 Mezzanine Slot 3 - PCIE Link
Width Error
Link Width error was detected on
Mezzanine Slot 3.
B374 Mezzanine Slot 4 - PCIE Link
Width Error
Link Width error was detected on
Mezzanine Slot 4.
B378 PCI Slot - PCIE Link Failure
Connection failure of PCIe bus was
detected on PCI slot
B37A I/O Blade PCI Slot - PCIE Link
Width Error
Link Width error was detected on I/O
Blade PCI Slot.
B3A0 CLP
Command
Failure
CLP Command failed to execute on
BIOS.
B3A1 EM Failure Pause
CLP Command failed to set on EM.
C010 The error occurred during
temperature sensor reading
An error occurred while reading the
temperature sensor.
C011 System Temperature out of the
range.
A temperature abnormality was
detected.
It is possible that a fan has failed or is
clogged. Contact your sales
representative.
C020 The error occurred during
voltage sensor reading.
An error occurred while reading the
voltage sensor.
Contact your sales representative.
C021 System Voltage out of the
range.
A system voltage abnormality was
detected.
C040 SROM data read error
SROM data reading error of FRU
C041 SROM data checksum bad
SROM checksum error of FRU
C061 1st SMBus device Error
detected.
An error occurred in the 1st SM Bus.
C062 2nd SMBus device Error
detected.
An error occurred in the 2nd SM
Bus.
C063 3rd SMBus device Error
detected.
An error occurred in the 3rd SM
Bus.
C064 4th SMBus device Error
detected.
An error occurred in the 4th SM Bus.
C065 5th SMBus device Error
detected.
An error occurred in the 5th SM Bus. Contact your sales representative.
C066 6th SMBus device Error
detected.
An error occurred in the 6th SM Bus.
C067 7th SMBus device Error
detected.
An error occurred in the 7th SM Bus.
C068 8th SMBus device Error
detected.
An error occurred in the 8th SM Bus.
C101 BMC Memory Test Failed.
BMC device (chip) error was
detected
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C102 BMC Firmware Code Area CRC
check
Failed.
C103 BMC core hardware failure.
C104 BMC IBF or OBF check failed.
Accessing the BMC address failed.
C105 BMC SEL area full.
There is not enough capacity to
write the system event log.
Run the Offline Tools and delete the event
logs.