Error Message
Cause
Solution
C10C BMC
update firmware corrupted.
An error was detected while
updating BMC firmware.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C10D Internal Use Area of BMC FRU
corrupted.
An illegality was detected in FRU
that stores the chassis information.
C10E BMC SDR Repository empty.
An error was detected on BMC
SDR.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C10F IPMB signal lines do not
respond.
Satellite Management Controller
(SMC) failure was detected.
C110 BMC FRU device failure.
Failure of the SROM for storing
chassis information was detected.
C111 BMC SDR Repository failure.
Failure of the SROM for storing
sensor data record data was
detected.
C112 BMC SEL device failure.
BMC device (chip) failure was
detected.
C113 BMC RAM test error.
BMC RAM error was detected.
C114 BMC Fatal hardware error.
BMC error was detected.
C115 Management
controller
not responding
Management controller does not
respond.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C116 Private I2C bus not
responding.
Private I2C bus does not respond.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C117 BMC internal exception
BMC internal error was detected.
C118 BMC A/D timeout error.
BMC A/D timeout error was
detected.
C119 SDR repository corrupt.
BMC error or illegal SDR data was
detected.
C11A SEL
corrupt.
BMC error or illegal system event
log data was detected.
C11B BMC Mezzanine card is not
found.
BMC Mezzanine card is not
mounted.
Contact your sales representative.
C11C BMC Mezzanine partition is
invalid.
BMC Mezzanine partition is invalid.
C11D BMC is in Forced Boot Mode.
Detected that BMC is in Forced Boot
Mode.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C11E Communication with BMC was
failed in previous boot
Communication with BMC was
failed in previous boot
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C11F Backup Data of BMC Mezzanine
card has corrupted.
Inconsistency was found on BMC
mezzanine card.
Contact your sales representative.