11. Advanced LAN Configuration
Express5800/B120g-h Maintenance Guide
139
Chapter 2 Useful Features
11.3
Precautions on Using vIO Control Feature
When configuring vIO on this server, the system may halt with a POST error message "Bxxx Expansion ROM
not initialized".
If this error occurs, select a port that is not used for PXE boot from the devices listed below, and specify "none"
for Boot Protocol of that port.
–
[N8403-094F] Dual Port 1GbE Riser Card Kit
–
[N8403-095F] Dual Port 10GbE Riser Card Kit
–
[N8403-096F] Dual Port 10GbE Riser Card Kit(iSCSI supported)
–
[N8403-097F] Dual Port 10GbE Adapter
–
[N8403-098F] Dual Port 10GbE Adapter(iSCSI supported)
–
[N8403-099F] Quad Port 10GbE Adapter
–
[N8403-100F] Quad Port 10GbE Adapter(iSCSI supported)
Described below are procedures to change parameter for Boot Protocol to "none".
The screen images and messages in this section are subject to change without notice. Substitute as appropriate
when content has been modified.
1. Power on the server.
2. Press <Ctrl> + <S> keys when the following message appears on the POST screen.
Configuration Menu
will be launched.
QLogic Ethernet Boot Agent
Copyright (C) 2014 QLogic Corporation
All rights reserved.
Press Ctrl-S to enter Configuration Menu
Tips
Press <Ctrl> key first, and then press <S> key.
If you fail to press the key and the following screen does not appear, restart the server
and press <Ctrl> + <S> keys again.