![NEC Express5800/B120g-h Maintenance Manual Download Page 96](http://html.mh-extra.com/html/nec/express5800-b120g-h/express5800-b120g-h_maintenance-manual_251263096.webp)
4. RAID System Configuration
Express5800/B120g-h Maintenance Guide
96
Chapter 2 Useful Features
4.3
Procedures for Using Configuration Utility
4.3.1
Create/add configuration
1.
Run LSI Software RAID Configuration Utility.
2.
From the TOP menu screen, select
Virtual Drive Management
, and then
Create Configuration
.
3. For
Select RAID Level
on the following screen, select the RAID level (RAID0, RAID1).
4.
Create a virtual drive. The procedure for creating a new virtual drive is different from that for adding a
virtual drive. Creating a new virtual drive is to create a virtual drive by using a new physical device.
Adding a virtual drive is to create an additional virtual drive by using an unused area of the existing
Drive Group.
Run LSI Software RAID Configuration Utility
Create/add Virtual Drive
Check the Virtual Drive settings
Initialize the Virtual Drive
Perform Consistency Check
Exit LSI Software RAID Configuration Utility
Install the OS and Universal RAID Utility*1
*1 This step is not required
if an virtual drive has
already been installed.