Electra Elite IPK
Document Revision 4
Programming Manual
2 - 495
___________________________________________________________________________________
___________________________________________________________________________________
3-73
CO Message Waiting Yes/No Selection
General Description
Use this Memory Block to specify whether or not the CO Message Waiting feature is
allowed per CO/PBX Line.
R2000 or higher is required.
Display
Settings
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
NO
YES
Programming Procedures
1
Go off-line.
2
Press LK3 +
G
+
GC
to access the Memory Block.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D
to go to the next assigned CO/PBX No.
Default Values
CO/PBX No. 01~64 = NO
3
Press the corresponding CO/PBX line key to change the Setting Data option.
4
Press
G
to write the selected data and display Memory Block 3-00 CO/PBX 02. After the last CO/PBX is programmed,
CO/PBX 01 is displayed again.
Related Programming
M.B. Number
Memory Block Name
1-8-07
Class of Service (Attendant) Feature Selection 1
Page 3, LK 2
4-69
CO Message Waiting Indication Assignment
CO/PBX Line Mode
3
Submode
—
Data No.
73
PC Programming
¦
+BCT
0 1 / 7 3 : C O M W
N O
T I M E
D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Setting
Data
Title