Electra Elite IPK
Document Revision 4
Programming Manual
2 - 423
___________________________________________________________________________________
___________________________________________________________________________________
2-08
ECR Relay to Tenant Assignment
General Description
Use this Memory Block to specify Tenant Assignment for External Tone Ring/Night
Chime function.
Display
Settings
Notes
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
Default not
assigned.
External
Tone Relay
1
External
Tone Relay
2
External
Tone Relay
3
External
Tone Relay
4
Night Chime
Programming Procedures
1
Go off-line.
2
Press LK2 +
KH
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
D
to go to the next assigned Tenant No.
Default Values
All Tenants No Assignment
4
Press the
G
to write the data. The next Memory Block is displayed.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-7-07
External Ring Relay Pattern Selection
1.
By assigning Night Chime to a Tenant, incoming calls to the Tenant group in Night Mode can be answered using
the Night Call Pickup Access Code.
2.
The relays are fixed (nonprogrammable).
3.
Night Chime must be assigned for Night Call Pickup to work. A relay may be assigned even when an ECR-U( )
ETU is not installed in the system.
Tenant Mode
2
Submode
—
Data No.
08
PC Programming
¦
+BN
0 0 / 0 8 : R L Y
T E N A N T
T I M E
D I S P L A Y
0 0 / 0 8 : R L Y
T E N A N T
T I M E
D I S P L A Y
Tenant
No.
(00~47)
Title
Data
No.