Electra Elite IPK
Document Revision 4
Programming Manual
2 - 291
___________________________________________________________________________________
___________________________________________________________________________________
1-11-02
Line Length Selection
General Description
Use this Memory Block to specify the distance, in feet, between the channel service
unit/demarcation (CSU/D mark) and the DTI-U( ) ETU. This specifies the equalization
values of the detect signal in the DTI-U( ) ETU.
Display
Settings
Notes
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
1
(0 - 131)
2
(132 - 262)
3
(263 - 393)
4
(394 - 524
5
(525 - 655)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK11 +
KB
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data. The next Memory Block is displayed.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
7-1
Card Interface Slot Assignment
The DTI-U( ) ETU must be assigned in the system to set this Memory Block.
System Mode
1
Submode
11
Data No.
02
PC Programming
¦
+AD
0 1 / 0 2 : L I N E
= 1
T I M E
D I S P L A Y
Data
No.
Setting
Data
DTI No.
(01~08)
Title
Line Key
LCD
Indication
Description
LK 1
1
0~131 feet
LK 2
2
132~262 feet
LK 3
3
263~393 feet
LK 4
4
394~524 feet
LK 5
5
525~655 feet
Summary of Contents for ElectraElite IPK
Page 2: ...PROGRAMMING MANUAL INT 1026 IPK Document Revision 4 Release 4000 4500 ...
Page 3: ......
Page 5: ......
Page 802: ...PROGRAMMING MANUAL NEC Unified Solutions Inc Document Revision 4 Release 4000 4500 ...
Page 803: ......