2 - 152
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
1-4-01
Automated Attendant First Digit PBR
Release Time Selection
General Description
Use this Memory Block to specify the time a Push Button Receiver (PBR) remains
connected after the Automated Attendant message is played when a calling party calls
in through an Automated Attendant trunk.
This Memory Block can be adjusted in 1-second intervals (R3000 or higher).
Display (R2500 or lower)
Settings
Refer to next page for R3000 or higher Programming Procedures.
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
5s
10s
20s
30s
40s
50s
60s
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 +
JA
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
System Mode
1
Submode
4
Data No.
01
PC Programming
¦
+AU
0 1 : A A
P B R T I M E 2 0 s
T I M E
D I S P L A Y
Setting
Data
Data
No.