Display (R3000 or higher)
Notes
Programming Procedures
1
Go off-line.
2
Press LK1 + LK2 +
KB
to access the Memory Block.
3
Use the dial pad to enter the Data Setting for Class 1.
Setting Data
00m~99m (e.g., 05m =5m)
Default Values
Class 1~4 = 30m
00m = No Limit
4
Press
G
to write the data and display the next Timer Class of Service.
5
Program the next Timer Class of Service or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
4-71
Station to Timer Class of Service (R3000 or higher)
1.
Telephone Ports 1 and 2 are in Station to Timer Class of Service, Class 1, by default. All other ports are in
Station to Timer Class of Service, Class 2, by default.
2.
When a system is upgraded from R2500 or lower to R3000 or higher, the Automatic Callback Release Time
Selection is reset to the default during the upgrade process.
0 2 : C A L L B A C K 1 = 3 0 M
T I M E
D I S P L A Y
Timer
Class
1~4
Title
Data
No.
Setting
Data