2-OPX Module
4-10
◆
Section 4: Optional Equipment
DS1000 Hardware Manual
2-OPX Module
Installing the 2-OPX Module
The 2-OPX Module (P/N 92177A) provides two 2500 type analog circuits for connection to on-premise
2500 type single line devices (i.e., telephones, fax machines, modems, etc.) and to telco OL13B/C OPX cir-
cuits. It uses a single digital extension circuit for the power and signaling for both analog ports.
Note: The 2-OPX Module is a discontinued item, but you may
fi
nd it at some installation sites.
To install a 2-OPX Module
(Figure 4-7)
:
1.
Install a modular jack for the 2 OPX Module within six feet of the module’s location.
2.
Run one-pair 24 AWG station cable from the cross-connect block to the modular jack.
3.
Terminate the station cable WHT/BLU - BLU/WHT leads to the RED and GRN lugs in the modular jack.
4.
Back at the main equipment location, run one pair of cross-connect wire between the pins on the exten-
sion block and cross-connect block to complete the connection.
5.
Install bridging clips as required.
6.
Ground the 2-OPX Module by connecting a 14 AWG ground wire from the FG lug on the module to a
known earth ground.
7.
Plug a line cord into the 2-OPX unit and the 2-OPX’s modular jack.
The DS1 LED on the 2-OPX Module lights steadily.
Figure 4-7: Connecting the 2-OPX Module
80000 - 41A
BLK
YEL
GRN
RED
Station
Block
Cross
Connect
Block
14 AWG from
FG lug to known
Earth Ground
BLU-WHT
WHT-BLU
625
Modular
Jack
One-Pair Cross-Connect
2-OPX Module
DS1
FG
Summary of Contents for DS1000
Page 6: ...Table of Contents iv Table of Contents DS1000 Hardware Manual...
Page 20: ...The Extension Block 2 4 Section 2 Trunk and Extension Cabling DS1000 Hardware Manual...
Page 42: ...Keyset Self Test 4 18 Section 4 Optional Equipment DS1000 Hardware Manual...
Page 58: ...Parts List 6 8 Section 6 Specifications and Parts DS1000 Hardware Manual...