System Load Factor Calculations
The combination of extensions, 2-OPX Modules, and DSS Consoles you can connect to your system may be
limited by the System Load Factor. Use the
DS1000 System Load Factor Calculations
chart to verify your
system’s con
fi
guration.
To check your system con
fi
guration:
1.
Indicate the quantity for each item installed in the
Qty
column.
2.
For each item, multiply the
Qty
times the
Load Factor
and enter the value in
Total Load
.
3.
Add all the values in the
Total Load
column and enter the value in
Item
1
.
4.
Compare the entry in
Item
2
to your entry in
Item
1
.
Item
1
must always be equal to or less than the
entry in
Item
2
.
Voice Mail Ports
Ports
Station Numbers
Extension Numbers
-
201-208
500-507
UCD Groups
Total Groups
UCD Group Master Extension Numbers
8
700-707
Ring Groups
Total Groups
Ring Group Master Extension Numbers
8
600-607
1
Available for digital station port secondary station numbers. These are used for the second channels on 2-OPX
Modules and Digital VANGARD Voice Mail.
Do not operate your system if the System Load Factor total (Item 1) exceeds the
allowable load of 30 (Item 2).
DS1000 System Load Factor Calculations
Description
Load Factor
Qty
Total Load
Digital Telephone
1
Analog Telephone
1
Analog Door Box
0
24-Button DSS Console
1
110-Button DSS Console
2
Total DSS Consoles installed cannot exceed 4
2-OPX Module
3
Item 1
: Total load for this con
fi
guration
Item 2
: Maximum allowable load
30
Default Numbering
Summary of Contents for DS1000
Page 6: ...Table of Contents iv Table of Contents DS1000 Hardware Manual...
Page 20: ...The Extension Block 2 4 Section 2 Trunk and Extension Cabling DS1000 Hardware Manual...
Page 42: ...Keyset Self Test 4 18 Section 4 Optional Equipment DS1000 Hardware Manual...
Page 58: ...Parts List 6 8 Section 6 Specifications and Parts DS1000 Hardware Manual...