Specifications
DS1000 Hardware Manual
Section 6: Speci
fi
cations and Parts
◆
6-5
6
Cabling Requirements
1.
Do not run station cable parallel with the AC source, telex or computer, etc. If the cables
are near cable runs to those devices, use shielded cable with grounded shields or install the
cable in conduit.
2.
When cables must be run on the
fl
oor, use cable protectors.
3.
Cable runs for key telephones, single line telephones, Door Boxes and 2-OPX Modules
must be a dedicated, isolated cable pair.
Device
Cable Type
Cable Run (ft)
Notes
Key Telephone
2-wire 26 AWG
2-wire 24 AWG
650
1000
Single Line
Telephone
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
8,000
12,000
16,000
at constant 20 mA
at constant 20 mA
at constant 20 mA
Analog Door Box
2-wire 24 AWG
2-wire 22 AWG
330
550
2-OPX Module
2-wire 24 AWG
1000