External Paging
4-2
◆
Section 4: Optional Equipment
DS1000 Hardware Manual
External Paging Relay Control
You can alternately use the 2 Door Box relays to control an External Paging ampli
fi
er. Figure 4-2
Connect-
ing an Analog Door Box
on page 4-4 shows you the location of the Door Box relays. Note that if you use a
relay for External Paging Control, you cannot also use it for Door Box strike control.
Connecting the Relays for External Paging Control
1.
If you are using the Door 1 relays, connect the BLK and YEL lugs on the Door Box 1 modular jack to
the relay that controls the External Paging system.
2.
If you are using the Door 2 relays, connect the BLK and YEL lugs on the Door Box 2 modular jack to
the relay that controls the External Paging system.
Programming the Relays for External Paging Control
●
In
0201 - Door 1 Relay
, to assign the Door 1 Relay for External Paging control, enter 2.
●
In
0201 - Page Zone (Door 1 Relay)
, enter the Page Zone (1-7) that should activate the Door 1 relay.
Note that Zone 1 and All Call Paging announcements broadcast from the External Paging output.
●
In
0201 - Door 2 Relay
, to assign the Door 2 Relay for External Paging control, enter 2.
●
In
0201 - Page Zone (Door 2 Relay)
, enter the Page Zone (1-7) that should activate the Door 2 relay.
Note that Zone 1 and All Call Paging announcements broadcast from the External Paging output.
Additional Programming
●
To adjust the External Paging ring volume:
- In
0202 - Page Ring Volume
, adjust the volume of ringing over External Paging (5=low, 6=medium,
4=high).
●
To enable Background Music over External Paging:
- In
0201 - Background Music
, enter Y (9) to enable Background Music system-wide.
- Make sure your music source is connected (
Music Source
on page 4-6 for more).
- In
0202 - Background Music Over External Page
, enter Y (9).
●
To enable Door Box chimes over External Paging:
- Make sure your Analog Door Box is correctly set up (see
Analog Door Box
on page 4-3).
- In
0202 - Door Chime Over External Page
, enter Y (9).
●
To enable extension ringing over External Paging:
- In
0202 - External Page Ring Source
, enter 3 (Extension).
- In
0202 - Extension,
enter the number of the extension that will ring over External Paging.
●
To enable trunk ringing over External Paging:
- In
0202 - External Page Ring Source
, enter 8 (Trunk).
- In
0203 - UNA Ringing Option
, specify the type of External Paging ringing for each trunk
(0=None, 1=Ring always, 2=Ring at night only, 3=Delay ring).
Refer to
Paging
in the
DS1000/2000 Software Manual
(P/N 80000SWG**) for more on these features.
!! Important !!
Be sure the devices connected to the system’s relay contacts
are compatible with the following speci
fi
cations.
Relay Contact Speci
fi
cations
Contact Con
fi
guration:
Normally Open
Maximum Load:
0.5A @ 120 VAC
1 A @ 24 VDC
Maximum Initial Contact Resistance:
100 mOhms
Summary of Contents for DS1000
Page 6: ...Table of Contents iv Table of Contents DS1000 Hardware Manual...
Page 20: ...The Extension Block 2 4 Section 2 Trunk and Extension Cabling DS1000 Hardware Manual...
Page 42: ...Keyset Self Test 4 18 Section 4 Optional Equipment DS1000 Hardware Manual...
Page 58: ...Parts List 6 8 Section 6 Specifications and Parts DS1000 Hardware Manual...