Section 4: Telephones and Optional Equipment
4-18
◆
Section 4: Telephones and Optional Equipment
Aspire S Hardware Manual
EXTERNAL PAGING
External Page
Two external page zone/door box circuits are provided by each 2PGDAD installed. Each Door Box/external
page circuit also provides a dry relay contact. In programming, the external page speakers provided by the
2PGDAD modules are numbered 1-8 - the relays on the 2PGDAD modules are numbered 1-8. Refer to Pag-
ing, External in the Software Manual for additional details.
The 2PGDAD module can be used for talkback with External Page, as can a CO trunk port with the proper
external page equipment (ex: Valcom) - set Program 31-06-03 to “0” for talkback.
NOTE: A 2PGDAD circuit used for External Paging cannot also be used for an analog Door
Box.
Installing an External Page System
1.
Connecting to the 2PGDAD Module:
Make sure the jumper in the 2PGDAD module for the channel is set correctly. (Refer to Figure 4-4
2.
If a line cord was not previously connected to the 2PGDAD, complete Steps 3-6. Otherwise, skip to
Step 7.
3.
Install a modular jack for each 2PGDAD module. For each module, run one-pair 24 AWG station
cable from the cross-connect block to a modular jack. Ground the unused pair(s).
4.
Terminate the extension leads to GRN/RED of the modular jack. Terminate the unused leads to the
jack.
5.
Install bridging clips as required.
6.
Plug a modular line cord from the mod jack to the CN1 connector on the 2PGDAD module.
7.
Connect the two-conductor station cable from the CN5 connectors within the 2PGDAD module to
the external relay/external page.
for further details on relays.