Installing a 110-Button DSS Console
1.
Install a modular jack for each 110-Button DSS Console. The modular jack should be within six
feet of the phone.
2.
For each 110-Button DSS Console, run one-pair 24 AWG station cable from the cross-connect
block to a modular jack. Ground the unused pair.
3.
Terminate the extension leads to GRN/RED of the modular jack. Terminate the unused leads to the
jack.
4.
Connect a line cord from the modular jack to the connector on the bottom of the DSS console.
Figure 4-12: INSTALLING A DSS CONSOLE
5.
To program a DSS Console . . .
With the default settings, there are no DSS Consoles assigned.
10-03-01 : PCB Setup
The system automatically assigns the terminal type (10) for the port which has a DSS console
installed.
When installing a DSS, the system must auto-detect the console in order for the LEDS to
function correctly. When connecting the DSS to a extension previously de
fi
ned with another
circuit type, unde
fi
ne the circuit type (enter 00 in Program 10-03 for the extension number),
then connect the DSS Console.
30-02-01 : DSS Console Extension Assignment
Designate the extensions that have DSS Consoles connected to them.
30-03-01 : DSS Console Key Assignment
Customize the functions of the DSS Console keys.
30-04-01 : Alternate DSS Console Key Assignment
If the console should have Alternate Answering, use this program to assign the Alternate Answering
Destination.
625
Modular
Jack
25-pair
cable to
extension
PCB
BLK
YEL
RED
GRN
BLU-WHT
WHT-BLU
Cross
Connect
Block
"B"
Block
0893100-111