1201 - DCI Setup
DCI S-Registers (Register Type 1) (cont’d)
20 times
0-65535 times
N2
After T1 expires, N2 is the
maximum number of trans-
mission and retransmissions
of a packet allowed.
4
2080 bits
0-65535 bits
N1
The maximum number of
bits in an I (Information
Transfer) frame
3
250 mS
0-65535 mS
T2 Timer
After the connected DTE
receives a packet from the
DCE, it must respond with-
in the T2 interval. (T2 must
be less than T1.)
2
500 mS
0-65535 mS
T1 Timer
After the DCE (DCI) sends
a packet, it must receive a
response from the connect-
ed DTE within the T1 inter-
val. If a response is not
received, the DCE resends
the packet.
1
Internal Calls
1 (hardware
flow control)
0=No flow control
1=RTS/CTS (hard-
ware) flow control
enabled
2=XON/XOFF
between DCI and
connected terminal
3=XON/XOFF
between sender
and receiver (DCI
transparent).
Flow Control
Sets flow control. For
PMS, be sure to disable
flow control (0).
0 (control
enabled)
0 = Control
enabled
1 = Disabled (fol-
lows RTS)
Clear to Send (CD)
Control
Enables (0) or disables (1)
CTS (pin5) control. If dis-
abled, CTS follows RTS
(pin 4). For PMS, always
enable this option (0).
Default
Range
Description
Register
3-28
3. Programming the
Hotel/Motel Options
92000hmt06.QXD 4/24/01 10:12 AM Page 28
Summary of Contents for 28i
Page 4: ...1 Introduction 1 2...
Page 8: ...1 Introduction For Your Notes 1 6...
Page 58: ...2 50 2 Hotel Motel Features For Your Notes...
Page 64: ...For Your Notes 3 6 3 Programming the Hotel Motel Options...
Page 102: ...For Your Notes 3 44 3 Programming the Hotel Motel Options...