Getting Started with MAXserver Access Servers
0038
27
Front Panel LEDs - MAXserver 1620/1640
The front panels of the MAXserver 1640 and 1620 access servers are
identical, except for the model designation. If, after several minutes, the
front panel lights do not behave as indicated, refer to the Troubleshooting
section of this guide for instructions.
XYPLEX MAXSERVER 1620
TERMINAL SERVER
1 2 3 4 5 6 7 8 9 10
RUN LAN CONSOLE
CARD
Reset switch
-- Press once to put the unit in reset state.
Press again to re-initialize the unit.
CONSOLE light
-- ON when someone is logged on to the
unit's console port via the network. Flashes if permanent
parameter changes have not yet been stored. (Do not power
off the unit while this light is flashing.)
LAN light
-- Flashes when the unit receives Ethernet
packets. Rapid blinking indicates heavy network traffic to the
unit.(OFF when not connected to network, or network is faulty.)
RUN light
-- ON when unit is reset; flashes rapidly when
unit executes firmware code; flashes slowly when software
is loaded (RUN state).
CARD light
-- ON when Memory card is being accessed.
Do not remove the card or power off the unit while this
light is ON.
Memory Card slot
Eject Button
Ports 1 - 10
-- These lights indicate port activity.
Flashing = activity on associated ports.
ON = port connection established.
OFF = no port connection established.
Figure 6 - MAXserver 1620/1640 Front Panel
Front Panel LEDs - MAXserver 1604/1608B
The front panels of the MAXserver 1604 and 1608B access servers are
identical, except for the model designation (see Figure 7). If, after several
minutes, the front panel lights do not behave as indicated, refer to the