Getting Started with MAXserver Access Servers
0038
35
XYPLEX MAXSERVER 1600
TERMINAL SERVER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
RUN LAN CONSOLE
CARD
X
Reset switch
-- Press once to put the unit in reset state.
Press again to re-initialize the unit.
Figure 10 - RESET Switch Location
3.
Use the paper clip tool to press the RESET button once. This halts all
MAXserver operations -- the server will no longer send or receive
network data or data from its connected devices. When the MAXserver
enters RESET state, all front panel lights illuminate.
4.
Press the RESET button again. The MAXserver begins its self test.
·
If the MAXserver detects an error, the front panel lights illuminate
as described in the Troubleshooting section of this guide. This error
sequence continually repeats until the error is corrected or you
power off the MAXserver. During this time, no data is exchanged
over the Ethernet cable or server ports.
·
If the MAXserver does not detect an error, it will begin loading
software from the flash card or begin requesting a network load (if
no flash card is present). Once loaded, the MAXserver resumes
normal operations.
If your MAXserver does not behave in this manner, see the Troubleshooting
section for advice.