NG1000 Troubleshooting Manual
Responding to alarms
Issue 0.4 2010-10-12
Page 1-9
Sys Con +5V Fault
CONTROLLER
This alarm occurs when the system controller’s +5 V
power supply’s output voltage is outside the
acceptable range of 4.7 V to 5.3 V. Suspect a possible
fault with the +5 V supply circuitry on the system
controller PWB (A1). To replace a system controller
PWB, see
“System Controller PWB Replacement” on
page 1-23
.
Sys Con +12V Fault
CONTROLLER
This alarm occurs when the system controller’s +12 V
power supply’s output voltage is outside the
acceptable range of 11.2 V to 12.8 V. Suspect a
possible fault with the +12 V supply circuitry on the
system controller PWB (A1). To replace a system
controller PWB, see
“System Controller PWB
Replacement” on page 1-23
.
System Fwd Pwr Low
CONTROLLER
This alarm occurs when the system’s RF output power
falls below the preset low power tone threshold
(configurable betweeen 25 and 75%). Check the
active transmitter for associated faults.
System High VSWR
CONTROLLER
This alarm occurs when the VSWR at the system’s RF
output exceeds 5.5:1. The transmitter system is
inhibited.
Sys Interlock Open
EXTERNAL
This alarm occurs when the external interlock circuit
for the overall system is not closed, inhibiting the
transmitter’s output. Check the interlock connection
between J1-1 and J1-2 on the system controller PWB.
If the interlock is intact, check all external interlock
switches. Otherwise, suspect a problem with the
interlock circuitry on the system controller PWB.
System Reset
N/A
This alarm occurs when a system reset is in progress.
Alarm (with Prefix)
Alarm/Status LED
Description and Troubleshooting Action
Summary of Contents for NG1000
Page 2: ......
Page 4: ......
Page 8: ...NG1000 Troubleshooting Manual Table of contents Page viii Issue 0 4 2010 10 12 ...
Page 10: ...NG1000 Troubleshooting Manual Page x Issue 0 4 2010 10 12 ...
Page 14: ...NG1000 Troubleshooting Manual Page xiv Issue 0 4 2010 10 12 ...
Page 22: ...NG1000 Troubleshooting Manual Page xxii Issue 0 4 2010 10 12 ...
Page 56: ...NG1000 Troubleshooting Manual Responding to alarms Page 1 34 Issue 0 4 2010 10 12 ...
Page 122: ...NG1000 Troubleshooting Manual Wiring connector lists Page 3 10 Issue 0 4 2010 10 12 ...
Page 128: ...NG1000 Troubleshooting Manual Reading Electrical Schematics Page 4 6 Issue 0 4 2010 10 12 ...
Page 153: ...Issue 0 4 2010 10 12 MD 6 Figure MD 6 NAPE82 Exciter Control PWB ...
Page 159: ...Issue 0 4 2010 10 12 MD 12 Figure MD 12 NAPA24 PA PWB C1 C2 C8 Q1 ...
Page 162: ...NG1000 Troubleshooting Manual List of terms Page 6 2 Issue 0 4 2010 10 12 ...
Page 163: ......