NG1000 Troubleshooting Manual
Responding to alarms
Issue 0.4 2010-10-12
Page 1-7
Table 1.1: Troubleshooting Alarms
Alarm (with Prefix)
Alarm/Status LED
Description and Troubleshooting Action
System Controller Generated Faults
AIn1(J11A-11) Fault
EXTERNAL
This alarm occurs when the analog input applied to the
auxiliary analog input 1 (pin 11 on
AUX I/O
connector
A1J11A) is in an alarm sensing condition, based on a
threshold defined by the user.
AIn2(J11A-12) Fault
EXTERNAL
This alarm occurs when the analog input applied to the
auxiliary analog input 2 (pin 12 on
AUX I/O
connector
A1J11A) is in an alarm sensing condition, based on a
threshold defined by the user.
AIn3(J11A-13) Fault
EXTERNAL
This alarm occurs when the analog input applied to the
auxiliary analog input 3 (pin 13 on
AUX I/O
connector
A1J11A) is in an alarm sensing condition, based on a
threshold defined by the user.
AIn4(J11A-14) Fault
EXTERNAL
This alarm occurs when the analog input applied to the
auxiliary analog input 4 (pin 14 on
AUX I/O
connector
A1J11A) is in an alarm sensing condition, based on a
threshold defined by the user.
Auto Chgover Event
CONTROLLER
This alarm occurs when an automatic transmitter
changeover occurs, typically due to the active
transmitter’s forward power falling below a preset
threshold. Check and troubleshoot the associated
transmitter for faults that may have caused the
changeover. Reset this alarm using a manual
changeover command or alarm reset.
Carrier Fault
CONTROLLER
This alarm occurs when the carrier frequency is off the
desired frequency by a preset amount (typically
12.5 kHz, or half a channel spacing).
Coax Interlock Open
EXTERNAL
This alarm occurs when the RF coaxial switch’s
internal interlock circuit is open. The system RF output
is inhibited by opening the associated transmitter
interlock circuits. If the troubleshooting tips do not
clear the alarm, replace the RF coaxial switch (see
“RF Coaxial Switch Replacement” on page 1-26
).
Summary of Contents for NG1000
Page 2: ......
Page 4: ......
Page 8: ...NG1000 Troubleshooting Manual Table of contents Page viii Issue 0 4 2010 10 12 ...
Page 10: ...NG1000 Troubleshooting Manual Page x Issue 0 4 2010 10 12 ...
Page 14: ...NG1000 Troubleshooting Manual Page xiv Issue 0 4 2010 10 12 ...
Page 22: ...NG1000 Troubleshooting Manual Page xxii Issue 0 4 2010 10 12 ...
Page 56: ...NG1000 Troubleshooting Manual Responding to alarms Page 1 34 Issue 0 4 2010 10 12 ...
Page 122: ...NG1000 Troubleshooting Manual Wiring connector lists Page 3 10 Issue 0 4 2010 10 12 ...
Page 128: ...NG1000 Troubleshooting Manual Reading Electrical Schematics Page 4 6 Issue 0 4 2010 10 12 ...
Page 153: ...Issue 0 4 2010 10 12 MD 6 Figure MD 6 NAPE82 Exciter Control PWB ...
Page 159: ...Issue 0 4 2010 10 12 MD 12 Figure MD 12 NAPA24 PA PWB C1 C2 C8 Q1 ...
Page 162: ...NG1000 Troubleshooting Manual List of terms Page 6 2 Issue 0 4 2010 10 12 ...
Page 163: ......