Unique symbols
Nautel uses unique symbols on electrical schematics to describe logic (two-state) signals. These
signals differ from single-state signals or analog signals that may have multiple values.
Type of inputs and outputs
On electrical schematics, names used to describe logic (two-state) input and output signals are
prefixed with a
#
symbol.
Logic level convention
The
#
prefix identifies an input or output signal that has two distinct states:
high
and
low
.
The suffix on an input or output signal name identifies the
active
(true) state of the signal. The
high
suffix
(+) indicates the more positive of the two levels used to represent the logic states. The
low suffix
(-) indicates the less positive of the two levels.
Two types of logic, positive and negative, may be represented on a particular schematic. In positive
logic,
high
represents the
active
(true) state, and
low
represents the
inactive
(false) state. In negative
logic,
low
represents the
active
(true) state, and
high
represents the
inactive
(false) state.
Identifying schematic diagrams
Each electrical schematic in this section is identified by a number that is both the figure number and
the page number. The numbers are assigned sequentially are prefixed by the letters
SD
. The electrical
schematics and logic diagrams included in this section are listed in
Table 4.1 on page 4-5
.
Structure of schematics
The electrical schematics are structured in a hierarchical format that is based on function and signal
flow. Wherever practical, the signal flow is from left to right. Normally, inputs originate on the left-
hand side and outputs extend to the right-hand side. Exceptions are shown by an arrow indicating the
direction of signal flow.
Note: The physical location of a part or assembly was not necessarily a factor during creation of the
schematic. The full reference designation assigned to a part or assembly, in conjunction with the family
tree (see
Section 3, “Parts Lists” on page 3-1
) and the assembly detail drawings (see
Section
6, “Mechanical Drawings” on page 6-1
), will identify its location.
Summary of Contents for NG1000
Page 2: ......
Page 4: ......
Page 8: ...NG1000 Troubleshooting Manual Table of contents Page viii Issue 0 4 2010 10 12 ...
Page 10: ...NG1000 Troubleshooting Manual Page x Issue 0 4 2010 10 12 ...
Page 14: ...NG1000 Troubleshooting Manual Page xiv Issue 0 4 2010 10 12 ...
Page 22: ...NG1000 Troubleshooting Manual Page xxii Issue 0 4 2010 10 12 ...
Page 56: ...NG1000 Troubleshooting Manual Responding to alarms Page 1 34 Issue 0 4 2010 10 12 ...
Page 122: ...NG1000 Troubleshooting Manual Wiring connector lists Page 3 10 Issue 0 4 2010 10 12 ...
Page 128: ...NG1000 Troubleshooting Manual Reading Electrical Schematics Page 4 6 Issue 0 4 2010 10 12 ...
Page 153: ...Issue 0 4 2010 10 12 MD 6 Figure MD 6 NAPE82 Exciter Control PWB ...
Page 159: ...Issue 0 4 2010 10 12 MD 12 Figure MD 12 NAPA24 PA PWB C1 C2 C8 Q1 ...
Page 162: ...NG1000 Troubleshooting Manual List of terms Page 6 2 Issue 0 4 2010 10 12 ...
Page 163: ......