[Default = blank (•) blank (•) from address 0460-0469]
Note:
If
Test Timer
is enabled (above),
Digital Dialer Test
is also enabled.
SYSTEM OPTIONS (ADDRESS 0460-0485 & 1054)
!
1. Select the desired option by circling
"
the data values for each digit (left
and right).
!
2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23).
!
3. Enter in address location (left and right digits).
NOTE:
Dark shaded data value box shows option not available.
!
4. Press
U
or
D
to save.
GLOBAL AMBUSH CODE:
It is the 2-digits entered immediately prior to the regular disarm code.
If “Enable Global Ambush Code” (Address 0720) is selected and Address 1054 is left blank (•), then
the 2-digit Global Ambush Code is “99”. If “Enable Global Ambush Code” is selected and Address
1054 is
not
left blank (•), then the 2-digit Global Ambush Code is the two digits entered in address
1054.
!
Enter in address location (both left and right digits) ; valid entries are 1-9.
!
Press
U
or
D
to save.
S
ys
tem
Op
tio
n
s
SYSTEM RESPONSE
ACTIVATED BY GLOBAL
GLOBAL SYSTEM EVENT/TROUBLE
LEFT DATA VALUES (CIRCLE
"
)
ADDRESS 0460-0469
EVENT/TROUBLE
Bell
Superv.
EZM
TAMPER
AC FAIL
LOW
BATTERY
L
ADDR
R
MEMORY
FAILURE
RF RCVR.
TROUBLE
TELCO
FAILURE
TEST
TIMER
Alarm Output
8
4
2
1
0460
8
4
2
1
Pulsed Alarm Output
8
4
2
1
0461
8
4
2
1
PGM1 Output
8
4
2
1
0462
8
4
2
1
PGM2 Output
8
4
2
1
0463
8
4
2
1
Report Event Telco 1
8
4
2
1
0464
8
4
2
1
Report Restore Telco 1
8
4
2
1
0465
8
4
2
1
Report Event Telco 3
8
4
2
1
0468
8
4
2
1
Report Restore Telco 3
8
4
2
1
0469
8
4
2
1
GLOBAL SYSTEM EVENT/TROUBLE
RIGHT DATA VALUES (CIRCLE
"
)
* NOTE:
Keypad Aux. is not to be selected for
UL Installations.
[Default = blank (•) blank (•) from address 0470-0477]
SYSTEM RESPONSE
ACTIVATED BY AREA 1
AREA 1 SYSTEM EVENT/TROUBLE
LEFT DATA VALUES (CIRCLE
"
)
ADDRESS 0470-0477
EVENT/TROUBLE
Keyfob
Low Batt.
FAIL TO
CLOSE
FAIL TO
OPEN
KEYPAD
TAMPER
L
ADDR
R
KEYPAD
AUX. *
KEYPAD
FIRE
KEYPAD
PANIC
AMBUSH
Pulsed Alarm Output
8
4
2
1
0470
8
4
2
1
Alarm Output
8
4
2
1
0471
8
4
2
1
PGM1 Output
8
4
2
1
0472
8
4
2
1
PGM2 Output
8
4
2
1
0474
8
4
2
1
Report Event Telco 1
8
4
2
1
0475
8
4
2
1
Report Event Telco 3
8
4
2
1
0477
8
4
2
1
AREA 1 SYSTEM EVENT/TROUBLE
RIGHT DATA VALUES (CIRCLE
"
)
* NOTE:
Keypad Aux. is not to be selected for
UL Installations.
[Default = blank (•) blank (•) from address 0478-0485]
SYSTEM RESPONSE
ACTIVATED BY AREA 2
AREA 2 SYSTEM EVENT/TROUBLE
LEFT DATA VALUES (CIRCLE
"
)
ADDRESS 0478-0485
EVENT/TROUBLE
Keyfob
Low Batt.
FAIL TO
CLOSE
FAIL TO
OPEN
KEYPAD
TAMPER
LEFT
ADDR
RIGHT
KEYPAD
AUX. *
KEYPAD
FIRE
KEYPAD
PANIC
AMBUSH
Pulsed Alarm Output
8
4
2
1
0478
8
4
2
1
Alarm Output
8
4
2
1
0479
8
4
2
1
PGM1 Output
8
4
2
1
0480
8
4
2
1
PGM2 Output
8
4
2
1
0482
8
4
2
1
Report Event Telco 1
8
4
2
1
0483
8
4
2
1
Report Event Telco 3
8
4
2
1
0485
8
4
2
1
AREA 2 SYSTEM EVENT/TROUBLE
RIGHT DATA VALUES (CIRCLE
"
)
[Default = blank (•) blank (•)]
Global
LEFT
RIGHT
Ambush Code
ADDRESS 1054